Serial Commands
Diagnostics Output 1 <K790,unused,service unit>
Diagnostics Output 2 <K791,unused,service unit>
Diagnostics Output 3 <K792,unused,service unit>
Symbol Quality Output 1
<K800,Output on Symbol Contrast,Symbol Contrast Threshold,
Output on Print Growth,Print Growth Threshold,Output on Axial
Non-Uniformity,Axial Non-Uniformity Threshold,Output on
Unused ECC,Unused ECC Threshold>
Symbol Quality Output 2
<K801,Output on Symbol Contrast,Symbol Contrast Threshold,
Output on Print Growth,Print Growth Threshold,Output on Axial
Non-Uniformity,Axial Non-Uniformity Threshold,Output on
Unused ECC,Unused ECC Threshold>
Symbol Quality Output 3
<K802,Output on Symbol Contrast,Symbol Contrast Threshold,
Output on Print Growth,Print Growth Threshold,Output on Axial
Non-Uniformity,Axial Non-Uniformity Threshold,Output on
Unused ECC,Unused ECC Threshold>
Output 1 Parameters <K810,output on,output state,pulse width,output mode>
Output 2 Parameters <K811,output on,output state,pulse width,output mode>
Output 3 Parameters <K812,output on,output state,pulse width,output mode>
Matchcode
Matchcode
<K223,matchcode type,sequential matching,match start position,
match length,wild card,sequence on no read,sequence on mismatch>
Master Symbol Database Size <K224,number of master symbols>
New Master Pin <K225,status>
Master Symbol <K231,index,master symbol data>
Match Replace <K735,status,replacement string>
Mismatch Replace <K736,status,replacement string>
Diagnostics
Hours Since Reset (Read-only) <K407> (returns: hours,minutes)
Service Message <K409,status,service message, threshold,resolution>
User-Defined Name <K412,user-defined name>
Output Format
Format Extract <K740,output index,start location,length>
Format Insert <K741,output index,length,hex string>
Format Assign <K742,symbol number,status>
Output Format Status <K743,output format status>
Output Filter Configuration
<K744,filter number,symbology,length,wildcard,placeholder,
data,unused,database index>
Output Filter Enable <K745,number of filters>