User`s manual
QX Hawk Industrial Imager User’s Manual A-55
Appendices
Quality Output
Separator
Decodes per Trigger Status
Symbol Data Output
Symbol Data Output Status
When to Output Symbol Data
Symbology ID Output Status
Read Duration Output
Read Duration Output Mode
Read Duration Output Separator
Serial Cmd: <K704,separator,decodes per trigger status>
Default: , (comma)
Options: Any 7-bit ASCII character
Serial Cmd: <K704,separator,decodes per trigger status>
Default: 0 = Disabled
Options: 0 = Disabled 1 = Enabled
Serial Cmd: <K705,symbol data output status,when to output,symbology i.d. output
status>
Default: 3 = Good Read
Options: 0 = Disabled 1 = Match 2 = Mismatch
3 = Good Read
Serial Cmd: <K705,symbol data output status,when to output,symbology i.d. output
status>
Default: 0 = As Soon As Possible
Options: 0 = ASAP 1 = End of Read Cycle
Serial Cmd: <K705,symbol data output status,when to output,symbology i.d. output
status>
Default: 0 = Disabled
Options: 0 = Disabled 1 = Enabled (AIM-Defined ID) 2 = Readable ID
Serial Cmd: <K706,status,separator>
Default: 0 = Disabled
Options: 0 = Disabled 1 = Enabled
Serial Cmd: <K706,status,separator>
Default: Space (0x20)
Options: Any 7-bit ASCII character