User`s manual
A-58 QX Hawk Industrial Imager User’s Manual
Serial Commands
EZ Button
Global Status
Default on Power-On
EZ Button Modes
Trend Analysis Output 1
Trend Analysis Mode
Serial Cmd: <K770,global status,default on power-on>
Default: 1 = Enabled
Options: 0 = Disabled
1 = Enabled
2 = Trigger
3 = Unlatch Outputs
4 = Parameter Switch
Serial Cmd: <K770,global status,default on power-on>
Default: 1 = Enabled
Options: 0 = Disabled 1 = Enabled
Serial Cmd: <K771,first beep,second beep,third beep,fourth beep>
Options: 0 = Disabled 1 = Enabled
Single Beep Two Beeps Three Beeps Four Beeps
0 = Disabled 0 = Disabled 0 = Disabled 0 = Disabled
1 = Read Rate 1 = Read Rate 1 = Read Rate 1 = Read Rate
2 = Calibrate 2 = Calibrate 2 = Calibrate 2 = Calibrate
3 = Save for Power-On 3 = Save for Power-On 3 = Save for Power-On
3 = Save for Power-On
4 = Unused 4 = Unused 4 = Unused 4 = Unused
5 = Load New Master 5 = Load New Master 5 = Load New Master 5 = Load New Master
6 = Unused 6 = Unused 6 = Unused 6 = Unused
7 = Target System 7 = Target System 7 = Target System 7 = Target System
8 = Unused 8 = Unused 8 = Unused 8 = Unused
9 = Bar Code Config. 9 = Bar Code Config. 9 = Bar Code Config. 9 = Bar Code Config.
Serial Cmd:
<
K780,trend analysis mode
,trigger evaluation period,number to output on,
decodes per trigger threshold>
Default: 1 = No Read
Options: 0 = Mismatch
1 = No Read
2 = Decodes per Trigger