Technical data

MANUAL JI REV 1.6 EN.DOC 31.01.07 A.J.
4
Technical Data
Zone 0 Zone 1 Zone 22
International ignition
protection:
II 1 G EEx ia IIB T4 II 2 G EEx ia IIC T4 II 3 D T60°C IP6X
Ex ia IIB T4 Ex ia IIC T4 Ex T60°C IP6X
Operating temperature:
(10 to 90% rel. humidity, n. c.)
Ta: -20°C ... +60°C
(-4°F to 140°F)
Ta: -40°C ... +70°C
(-40°F to 158°F)
Ta: -25°C ... +60°C
(-13°F to 140°F)
License: TÜV 04 ATEX 2459 TÜV 04 ATEX 2459 TÜV 04 ATEX 2647X
Housing material: Sheet steel / aluminum
Housing dimensions: see drawings
International Protection Encl.: Front side IP66 (NEMA 4X9 with expert installation.
Connection supply: Pin K44 2 x (0.5-2.5)mm² rigid / flexible
or connecting line
Connection interface: Pin K44 2 x (0.5-2.5)mm² rigid / flexible
or connecting line
Storage temperature: -20 °C - +60°C (-4°F to 140°F), 10 to 90% rel. humidity, n. cond.
Type Ji:
Supply voltage: Via intrinsically safe supply unit with the technical data:
U
max
5.5 V, I
min
> 14 mA
C
imax
19uF, L
i
negligible
Type Ji-B6:
Supply voltage: Via intrinsically safe supply unit with the technical data:
U
max
6.25 V, I
min
> 14 mA
C
i
, L
i
negligible
Type Ji-B12:
Supply voltage: Via intrinsically safe supply unit with the technical data:
U
max
12.5 V, I
min
> 14 mA
C
i
, L
i
negligible
Technical Data Data Via intrinsically safe interface with the technical data:
circuit all Ji types: Ui
max
5.5 V
U
o
5.5V, I
o
142mA, P
o
105mW
C
i
, L
i
negligible
Material joystick gaiter- Neoprene
protector:
Max. admissible load: 300N
Further details can be found in the license.