CRYOCOOL Systems Product Manual This manual covers the following units Air cooled under counter units CRYO 10 AU CRYO 20 AU CRYO 30 AU CRYO 40 AU Air cooled floor standing units CRYO 40 AF CRYO 50 AF CRYO 60 AF CRYO 70 AF CRYO 90 AF CRYO 100 AF Water cooled floor standing units CRYO 80 WF CRYO 100 WF Issue 2 06/05/05
Contents Page The System Product Overview Configuration 3 3 Handling and transportation 3 Location 3-4 Installation CRYO AU & AF Coolers CRYO WF and Discharge Coolers Product Lines Bypass Valve Trace Cooling Glycol lines/Wiring Cellar Checklist Bar Checklist 4 5 5 5 5 6 7 8 Commissioning Trace Cooling 9 Product Supply Cleaning Lines Cleaning Socket Labels 9 9 Maintenance 10 System Schematics 11-12 Spares Lists and Exploded Views 13-16 Fault Finding 17-18 Glycol Freezing points Brix mi
The System Product overview A range of draught beer dispense glycol cooling systems delivering consistently cold temperatures (between 2oC and 4oC) from a minimum of one dispense point in the CRYO 10 AU to a maximum of 14 dispense points in the CRYO 90 AF/100 WF. The system utilises a CRYO system cooler containing a sub zero coolant. Product is cooled in coils which are immersed in the sub zero coolant.
Location continued Floor mounted CRYO WF coolers The CRYO WF coolers may be sited within cooled cellars, store rooms or other appropriate internal areas where the ambient air temperature will not exceed 40°C, however when used in the CRYOCOOL system it is better to site the CRYO WF coolers in the temperature controlled product store. The CRYO WF coolers should not be exposed to liquid spillage, spray, steam or high humidity.
CRYO WF and Discharge Cooler Warning, this appliance must be earthed! Caution, avoid spilling the glycol mix, wipe excess glycol away as it is slippery! Installation must only be carried out by a suitably trained person and comply with national and local codes for connection to electrical supply. It is recommended that the mains electrical supply is protected by an RCCB.
Glycol Lines/Wiring (CRYO WF units only) Using a minimum 1.5mm2 two core cable for a maximum 50m run, connect the Discharge Cooler to the CRYO WF cooler. Connect the two core cable to the bottom two pins on the plug. The plug socket is located at the rear of the CRYO WF cooler (Note: This is a nominal 24 volt supply). Complete the glycol circuit by connecting the pipe work between the CRYO WF cooler and the discharge cooler with the aid of the fittings provided.
CRYOCOOL Installation Check list These sheets are intended as a guide to a method of installation of the CRYOCOOL System.
Bar Installation 1 Site coolers (CRYO AU only) 2 Run python into position in bar 3 Pull out product lines from python close to and beneath relevant font re-taping as you go 4 Fit flow control to product lines (not supplied) keeping 3/8 pipe to minimum between flow control and python 5 Connect restrictor tube between flow controls and taps. Tape and insulate 6 Fit trace cooling tees into python as required and insulate 7 Fit Pressure Balancing valve between flow and return.
Commissioning The CRYO coolers will cool glycol to a sub zero temperature- DO NOT TOUCH. Before switching the CRYO AU, AF & WF to ‘cool’ mode ensure that all coils are purged with product! Commissioning can only be successfully completed when: • Recirculation pump is running and all components are installed and connected • Glycol bath temperature remains between set range of temperatures. Ensure products dispensed at between 2°C and 4°C.
Maintenance (Faults/Repairs) • • • There are no user serviceable items inside the equipment. Maintenance must only be carried out by a properly qualified and trained person. Switch off the mains supply and unplug the equipment if it malfunctions or receives any physical damage causing it to become unsafe and/or working outside the parameters set in this document. User Maintenance • • • • • Switch off and unplug the unit during maintenance operations. Do not remove any protective covers.
System Schematic Bar and Cellar area CRYO AU/AF/WF ΙΜΙ ΧΟΡΝΕΛΙΥΣ (ΥΚ) ΛΤ∆ 11
System Schematic Bar area CRYO AU/AF/WF 12
SPARES LIST CRYO 80 & 100 WF ITEM PART No.
EXPLODED VIEW CRYO 80 & 100 WF SYSTEM SPARES CRYOCOOL PART No. CZZ 096 122 402 PART No. DESCRIPTION 96VA TRANSFORMER DESCRIPTION 07 0 001589 INSULATED STRAINER PART No. 07 0 001587 DESCRIPTION DIFFERENTIAL PRESSURE VALVE PART No.
SPARES LIST CRYO 50 & 60 AF ITEM 1 PART No.
EXPLODED VIEW CRYO 50 AF 16
CRYOCOOL SYSTEM Is Cooler plugged in and No Cooling Yes Is cooling problem restricted to one cooler? Is Cooler plugged in and turned on? No Plug in cooler and turn on Yes Is the Glycol/water mix between -2o and -4oC? No Yes See CRYO 100 WF fault finding below Is top pump working correctly? No Yes Check cellar temp. and the length of time the product has been stored in the cellar No CRYO 100 WF is working correctly Yes Product temp. correct Correct the cellar temp.
Fault Finding cont..
Glycol Glycol Freezing Points A 30/70 mix of Glycol/Water has a freezing point at around -14ºC (Refer to Graph 1) Graph 1.
Glycol Mix Brix A 30/70 mix of Glycol/Water has a sugar percentage (Brix) of around 20% (Refer to Graph 2) Graph 2.
Refractometer Usage Instructions for the use of the hand refractometer for measuring Glycol/Water Concentrations Calibration • Flip open the daylight plate, which covers the prism. • Apply one or two drops of clean tap water onto the prism, using a soft applicator, such as a cable tie. • Close the daylight plate. • Holding the refractometer up to the light, look at the scale through the eyepiece, turning the eyepiece assembly until the boundary line, created by the water, is in sharp focus.