e User Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER
INTRODUCTION Contents Page Introduction Things you should know Getting started How to… What if… Setting the Vokera…. Dear customer Do’s and don’ts 1.1 Gas appliances 1.2 Electrical supply 1.3 Guarantee registration card 1.4 Benchmark log book 1.5 How does it work? 1.6 Additional features 1.7 Dimensions 1.8 Clearances 1.9 Filling valve 2.1 Before switching on 2.2 Appliance controls 2.3 Lighting the boiler 3.1 Top-up the system 3.2 Reset the appliance 3.3 Understand the diagnostic fault codes 3.
INTRODUCTION 4 1 Fig. 1 1. 2. 3. 4. 5. 6. 7. 8. 9. 5 6 7 2 8 9 3 Pressure gauge Clock aperture N/A Hot Water temperature selector Mode selector switch Status LED Digital display Heating temperature selector DHW request LED Filling valve Filling Loop Isolating valve Fig.
THINGS YOU SHOULD KNOW 1.1 1.2 GUARANTEE REGISTRATION CARD Please take the time to fill out your guarantee registration card. The completed warranty card should be posted within 30 days of installation. 1.4 BENCHMARK LOG BOOK The Benchmark Log Book is supplied with your boiler. This important document must be completed during the installation/commissioning of your boiler. All CORGI Registered Installers carry a CORGI ID card and have a registration number.
1.9 FILLING VALVE The filling valve is located underneath the boiler. The filling valve lever has 3 positions: ● normal operating position ● closed position ● filling position. Normal Operating Position The valve lever should never be turned to the filling position unless the filling loop has been connected and the system pressure requires toppingup (see 3.1). Closed Position Filling Position Fig. 3 GETTING STARTED 2.
HOW TO..... 3.1 HOWTOTOP-UPTHE SYSTEM PRESSURE (fig. 2) The system pressure must be checked periodically to ensure the correct operation of the boiler. The needle on the gauge should be reading between 1 and 1.5 bar when the boiler is in an off position and has cooled to room temperature. If the pressure requires ‘topping-up’ use the following instructions as a guide. ● Locate the filling valve connections (below the boiler). ● Attach the filling loop to both connections.
WHAT IF.... 4.1 WHAT IF I SUSPECT A GAS LEAK If you suspect a gas leak, turn off the gas supply at the gas meter, and contact your installer or local gas supplier. If you require further advice please contact your nearest Vokera office. 4.2 WHAT IF I HAVE TO FREQUENTLY TOP-UP THE SYSTEM If the system regularly requires topping-up, it may be indicative of a leak. Please contact your installer and ask him to inspect the system. 4.
VOKERA RC05 REMOTE CONTROL DESCRIPTION OF CONTROL PANEL DESCRIPTION OF BUTTONS Regulates the heating and domestic hot water temperature Makes a temporary change in level Programs the boiler Changes mode (OFF-SUMMER-WINTER) Sets cleaning and holiday function Increases setting Selects and confirms data and changes room temperature Decreases setting Releases boiler, reset data and tests display e 7
VOKERA RC05 REMOTE CONTROL DESCRIPTION OF DISPLAY 15 16 19 2 1 7 8 9 3 10 4 11 5 14 6 13 12 18 17 1- Boiler lockout indicator 10 - Boiler control indicator 2- Heat request indicator 11 - Underfloor heating function indicator 3- Heating indicator 12 - Thermoregulation status indicator 4- Domestic hot water indicator 13 - Cleaning/holiday function indicator 5- Economy level temperature indicator 14 - Telephone interface function indicator 6- Comfort level temperature ind
VOKERA TIME CLOCK 5.1 5.1.1 SETTING THE MECHANICAL CLOCK The Vokera mechanical time clock can automatically switch your boiler on and off at the same time every day of the week. The minimum ’on’ or ‘off’ period can be as little as 15 minutes. The outer clock face consists of 96 black pins. Each pin represents a time period of fifteen minutes.
5.2.3 Fig. 4 5.2.4 HELPFUL HINTS ● You can check and/or alter the programme settings at any time by pressing the Prog button. ● The number of unused ‘commands’ can be checked by pressing the Prog button until FR is displayed alongside the number of unused commands. ● In the event of a power failure, the clock has a battery back-up. The programme will be held in the memory for approximately 2 weeks. Charging time is 70 hours.
Cod. 10025944 - 18/04 - Ed. 1 energizing home heating Vokèra Ltd. 4th Floor, Catherine House, Boundary Way, Hemel Hempstead, Herts, HP2 7RP Email: enquiries@vokera.co.uk Web: www.vokera.co.uk Sales, Technical Advice, General Enquiries - Tel: 0870 333 0520 Fax: 01442 281403 After Sales Service - Tel: 0870 333 0220 Vokèra Ireland West Court, Callan, Co Kilkenny Tel: 05677 55057 Fax: 05677 55060 Vokèra Ltd. reserve the right to change the specifications without prior notice.