Repair Manual

60. Lube oil pump "O" ring and seal surface of the
converter cover with Trans-Jel®.
61. Apply 1/8 inch bead of RTV sealant to converter
cover, as shown in Figure 193.
62. Ensure oil pump to converter cover seal is still
in place, as shown in Figure 195.
63. Install the converter cover assembly, as shown in
Figure 195, using the chart in Figure 194 for the
bolt locations.
64. Torque all converter housing retaining bolts to
19 N·m (14 ft.lb.).
Figure 194
{
{
1 Behind Bell
Housing Here
21 Total
2 Behind Bell
Housing Here
"B" = BOLT 83 MM LENGTH (1 REQUIRED).
"C" = BOLT 45 MM LENGTH (1 REQUIRED).
"A" = BOLT 30 MM LENGTH (17 REQUIRED.
B
A
A
A
A
A
A
A
A
A A
A
A
C
A
A
AA
D
D
Copyright © 2010 ATSG
113
AUTOMATIC TRANSMISSION SERVICE GROUP
Technical Service Information
Figure 193
TRANSAXLE FINAL ASSEMBLY (CONT'D)
7
4051 - 1 - 1
03C2T02168
Z
0300 035H
09G
1004
32
1 6 C
A
49 BOLT 30 MM LENGTH (17 REQUIRED).
50 BOLT 45 MM LENGTH (1 REQUIRED).
51 BOLT 83 MM LENGTH (1 REQUIRED).
52 STUD BOLT 30 MM LENGTH (2 REQUIRED)
Figure 195
49
50
52
51
Copyright © 2010 ATSG
1/8" BEAD OF
RTV SEALANT
Copyright © 2010 ATSG
Continued on Page 114