Repair Manual

Solenoids SV3, 5, 9 and 10 are Normally Applied, which applies their assigned component when they are Off. They are
Energized (On) to release their assigned component. These solenoids are also Modulated, to control their assigned
component apply and release rates. Consult the charts above to compare the amperage to clutch application.
Solenoid SV6 (N93) is modulated based on engine load to control main line pressure. Amperage will decrease to increase
main line pressure.
Solenoid SV4 (N91) is modulated to control Torque Converter Clutch (TCC) apply and release rates, but dependends on the
SV2 (N89) solenoid to be On to stroke the TCC switch valve so that N91 can complete its assigned task. There will be situations
during Manual Tiptronic shifts, SV4 (N91) amperage will indicate .500 - .700 amps and the TCC will be Off, as SV2 (N89) is
"0" which indicates Off.
T = On in Tiptronic Mode
To = Solenoid is toggled On to Off
Solenoid Shift Sequence
Clutch Application Chart
On/Off
Solenoids
Clutch and Freewheel
Components
Pressure Control Solenoids
Gear
Shift
Position
Park
Neutral
Reverse
1st Gear
2nd Gear
3rd Gear
4th Gear
5th Gear
6th Gear
N89
SV-2
N92
SV-5
N282
SV-9
N90
SV-3
N283
SV-10
N91
SV-4
N93
SV-6
K1 K2 K3 B1 B2 F1
OFF PWM
PWM
OFF ON ON
ON ON ON ON
ON ON OFF ON
OFF ON ON ON
OFF ON ON OFF
OFF ON OFF ON
OFF OFF ON ON
ON OFF OFF ON
ON OFF ON OFF
PWM
PWM
PWM
PWM
PWM
PWM
PWM
PWM
PWM
PWM
PWM
PWMON
ON
ON ON
ON
ON
ON
ON ON
ON
ON
ON
ONON
ON
T T
ToT/To
ToT/To
ToT/To
To
N88
SV-1
SHIFT SOLENOID AND CLUTCH APPLICATION CHART
SOLENOID
RANGE GEAR
Park Reverse
Neut
Drive
1
Manual
1
2
3H
4H
5H
6M
3M
4M
5M
6H
SV5-N92 (K1)
SV9-N282 (K2)
SV3-N90 (K3)
SV10-N283 (B1)
SV6-N93 (LP)
SV4-N91 (TCC)
SV2-N89
SV1-N88
.100A
.100A
.980A
.980A
.980A
.200A
0
0
.980A
.980A
.100A
.980A
.980A
.200A
0
0
.980A
.980A
.980A
.980A
.980A
.200A
0
0
.200A
.100A
.980A
.980A
.980A
.980A
.200A
.100A
.980A
.980A
.980A
.740A
10
0
.100A .100A .100A .980A .980A
1
.980A
.980A
.100A
.860A
.200A
0
0
.980A
.100A
.980A
.980A
.990A
.200A
3H=0
3M=1
0*-1
.100A
.980A
.980A
.980A
.990A
.200A
4H=0
4M=1
.100A .100A
.980A
.100A
.740A .740A
.100A
.980A
.990A
.200A
5H=0
5M=1
.990A
.200A
6H=0
6M=1
.100A= Very Low amperage
Solenoid OFF
.980A= Very High amperage
Solenoid ON
SV1&2-N88&89
0 =OFF
1=ON
0*-1= OFF or ON
during shift transitions
3H = 3rd Gear TCC OFF
3M = 3rd Gear TCC ON
(This applies to gears 3-6)
0*-1 0*-1 0*-1
SOLENOID OBSERVED AMPERAGE CHART
13
Copyright © 2010 ATSG
AUTOMATIC TRANSMISSION SERVICE GROUP
Technical Service Information
Figure 14
WWW.ALL-TRANS.BY