Repair Manual
19
Copyright © 2010 ATSG
AUTOMATIC TRANSMISSION SERVICE GROUP
Technical Service Information
View looking into the TCM (J217)
View looking into the 52 pin TCM (J217) Connector
1 2
3 4 5 6 7 8 9 10 11 12 13 14
15 16 17 18 19 20 21 22 23 24 25 26
29 30 31 32
27 28
33 34 35 36 37 38 39 40
41 42 43 44 45 46 47 48 49 50 51 52
Solenoid
Number (Name)
Positive Meter Lead
Terminal No. (Wire Color)
Negative Meter Lead
Terminal No. (Wire Color)
Ohms
Resistance
Figure 22
RESISTANCE CHART THROUGH TCM 52-WAY CONNECTOR
Solenoid No. 1 (N88)
Solenoid No. 2 (N89)
Solenoid No. 3 (N90)
Solenoid No. 4 (N91)
Solenoid No. 5 (N92)
Solenoid No. 6 (N93)
Solenoid No. 9 (N282)
Solenoid No. 10 (N283)
TFT (G93)
ISS (G182)
OSS (G195)
PS-1 (G193)
PS-2 (G194)
41 (Violet/Blue)
15 (Violet/Green)
30 (Yellow/Gray)
44 (Yellow/Black)
8 (Blue/Black)
39 (Black)
50 (White)
43 (Gray/Black)
6 (Blue/White)
17 (Green/Blue)
32 (Violet)
18 (Violet/Gray)
42 (Yellow/Violet)
31 (Blue/Violet)
16 (Yellow/Green)
4 (Green)
45 (Blue/Brown)
51 (Green)
38 (Black/Brown)
24 (Green/Blue)
25 (Blue/Green)
5 (Brown)
1 or 2 (Brown)
1 or 2 (Brown)
1 or 2 (Brown)
1 or 2 (Brown)
10 - 16
10 - 16
4.0-8.0
4.0-8.0
4.0-8.0
4.0-8.0
4.0-8.0
4.0-8.0
0 = Open
0 = Open
5.0M
5.0M
See Figure 21
External Harness wire colors provided in the chart above are from 2004 Audi TT, and may vary
depending on the year, make and model of the vehicle.
WWW.ALL-TRANS.BY