A status LED (4) indicates the function of the charger:
LED is off: No rechargeable battery connected/identied
LED lights up red: The charging process is under way
LED lights up green: The charging process is nished
LED ashes red: An error is indicated (for e.g. rechargeable battery deeply discharged,
cell voltage too high, etc.)
When the charging process is done, remove the rechargeable battery from the charger.
Now, either connect another rechargeable battery for charging, or disconnect the charger
from the mains voltage. Pull the mains plug out of the mains socket. Keep the product in a
cool, dry, dust-free place out of the reach of children.
Care and Cleaning
A connected rechargeable battery must be unplugged before cleaning. Disconnect the char-
ger from the mains voltage. Pull the power plug out of the mains socket.
Do not use abrasive cleaning agents, cleaning alcohol or other chemical solutions, since
these could damage the housing or even impair operation.
Use a dry, lint-free cloth to clean the product.
Disposal
a) Product
Electronic devices are recyclable material and do not belong in the household was-
te. Dispose of the unserviceable product in accordance with the relevant statutory
regulations.
b) Batteries/rechargeable batteries
As the end user, you are required by law (Battery Ordinance) to return all spent batteries/
rechargeable batteries; disposal of them in the household waste is prohibited.
Batteries/rechargeable batteries contain harmful materials and are labelled with the
symbol shown to indicate that disposal in the household waste is forbidden. The
symbols of the relevant heavy metals are: Cd=cadmium, Hg=mercury, Pb=lead (the
marking can be seen on the battery/rechargeable battery, e.g. underneath the refu-
se bin symbol shown on the left).
You can return used batteries/rechargeable batteries free of charge to any collection facility in
your local authority, to our stores or to any other store where batteries/rechargeable batteries
are sold.
You thereby full your statutory obligations and contribute to the protection of the environment.
Technical Data
Operating voltage ............................... 100 - 240 V/AC, 50/60 Hz
Protection class .................................. II
Charging jacks .................................... XH balancer connection
Appropriate rechargeable battery ....... LiPo (with rated voltage per cell 3.7 V)
Number of cells ................................... 2 - 3
Battery capacity .................................. 500 - 3000 mAh
Charging current ................................. max. 1 A
Balancer current ................................. 400 mA
Charging capacity ............................... 10 W
Shut-down voltage .............................. 4.20 V (per cell)
Short-circuit protection ........................ yes
Ambient conditions ............................. Temperature from +10 °C to +40 °C, air humidity 0% to
90% relative, not condensing
Dimensions (L x W x H) ...................... 97.6 x 56 x 28.8 mm
Weight ................................................ 100 g