8. REMOTE CONTROL
Observe:
Thissectiondoesnotapplytotheconverterswithcigarettelighterplug"SW-100"(itemno.511700)and
"SW-150"(itemno.511743and511744),sincetheydonothavearemotecontrolinput.
Theconvertercanbeswitchedonoroffviaanexternalswitch(nobutton!).
For connection of the remote control, we recommend a 2-wire switching strand with a line cross-section of at least
0.5mm².Thecablemaybeupto10mlong.
Theon/offswitchmaybeanyswitch,sincetheinternaldirectvoltageisusedasaswitchingvoltage(nomainsvolt-
age is pending at the switching contact).
A matching round plug with cable is enclosed with the converter.
Attention!
The open ends of the lines of the remote control cable must not touch the housing of the converter since
this would destroy the inverter! Loss of guarantee/warranty!
9. LED DISPLAY
The LED display of the converter can be used to recognise different conditions.
LED is lit green
The converter is operated within the permitted thresholds.
LEDashesred
The rechargeable battery voltage is below the rated voltage. Depending on the power intake of the connected
consumer, deactivation must be expected at continued operation.
LED is lit red
• Thepermittedminimumvoltageattheinput(rechargeablebatteryconnection)hasbeenundercut.Therecharge-
able battery is discharged. To protect the rechargeable battery from harmful deep discharge, the mains voltage
output has been switched off. Reactivation is possible after the minimum activation voltage has been reached.
• Themaximumpermittedoutputcurrentoftheconverterhasbeenexceeded.Theoverloadmanagementhas
switched off the mains voltage output of the converter.
The connected consumer has an output that is too high for the converter or the start-up current/activation current
is too high. It would also be imaginable that the consumer is defective and causes a short circuit at the output of
the converter.
 Theconverternowtries5xevery5secondsandthenevery30secondstostartupagain;theLEDbrieylightsup
green during this. If the converter does not come on even after several start-up attempts, disconnect the consumer
from the output of the converter and check the function of the converter.
Also check the consumer at the public mains or have the consumer checked by a specialist if the protection ele-