Low charge capacity (C) although the battery was discharged
Process battery with the “ALV” (“ALIVE”) programme. If the charge capacity “C” is still too
low, the battery is defective.
No display in the device display and/or no reaction due to EMC impulses,
electrostatic discharge = ESD, surge impulses or line-conveyed interference
resistance
Disconnect the device from the power supply and reconnect it.
Significant warming on the casing
The high performance of the device results in heating of the top and bottom of the
casing; this is no fault; ensure good ventilation.