11. VARIOUS BASIC SETTINGS (“USER SET”)
In the main menu, select the “USER” menu with the button “Batt Type/Stop”.
USER SET
PROGRAM->
Follow the steps below to change any of the settings.
1. To select the parameter to change, press “Start/Enter” to make it blink.
2. To change the value, press the “Inc” or “Dec” key.
3. To store the value, press “Start/Enter” again.
4. To switch to the next setting, press “INC”. (Or press “Dec” to go back to the previous setting.
5. To return to the main menu, press “Batt Type/Stop”.
Changing the Lithium Battery Type
LiFe
V.Type 3.3V
Here you can select one of the three lithium battery types: (“LiPo”, “LiIo”, “LiFe”).
You can select the cell voltage “3.3”, “3.6” or “3.7”. At the same time, the corresponding battery type
changes in the top line.
The settings made here for the lithium battery type then applies for ALL other functions,
e.g. charging, discharging, etc. (see chapter 11).
Setting the Time to Check Cell Count
LiPo/LiIo/LiFe
CHK Time 10min
Here you can set the time in which the charger checks a connected lithium battery for the correct
cell count and terminates the charge process, if applicable. This may be especially helpful with deep
discharged batteries. For an battery with a higher capacity, set a longer time, for one with a lesser
capacity a correspondingly shorter time.
You can select the time from between 5 to 60 minutes.