BATTERY VOL ERR
CELL CONNECT
Wrong connection of the balancer cable or the pin assignment
does not match that of the charger.
BATTERY VOL ERR
CELL LOW VOL
The battery voltage is too low. Use storage mode to build up
the voltage rst before fully charging.
TEMP OVER ERR
Internal temperature too high. Cool down the charger and the
battery.
CONTROL FAILURE
The charger has established that there is an internal problem.
Should this message permanently be displayed, it is possible
that the charger is defective; have it checked by a specialist
workshop or qualied technician.
18. INFORMATION BY THE CHARGER
To display user settings
During a charge / discharge process, you can check your user settings. Press “DEC” to switch
between the various displays. The various displays are as follows :
End Voltage
12.6V(3S)
The voltage of the battery at the end of charging / discharging
process
Capacity Cut-OFF
ON 5000mAh
The status of the capacity cut-off function
Safety Timer
ON 200min
The status of the safety timer function
Temp Cut-Off
ON 80C 118F
The status of the temperature cut-off function
Ext.Temp 26C
Int.Temp 30C
Temperature measured by the internal and external
temperature sensor