User manual
29
ture data). The max. setting time of the Sampling Rate is 59 minutes and 59 seconds.
The shortest setting is 2s, that means every 2 s there are new screen contents
appearing (new measuring values).
The three buttons to the right of them for the "Normalcursor" (arrow symbol) the so-
called X-marker to set X-markings and the "T" for a text comment in the stopped
temperature writing.
To the right of it, there is the Clear button which serves to delete made settings.
To the right of it, there is the button for "Undo Zoom". If you have zoomed a detail
with the mouse (keep the left mouse key pressed) you can now undo this zoom with
the "Undo Zoom".
To the right of it (between "Undo Zoom" and "Graph Options"), there is a inconspi-
cuous field "Split". If you click this field, the measuring depiction will be split from
one-channel presentation to four-channel presentation and vice versa.
Graph Options
If you click this field, you will get to a further window which is called "Customization".
With this field and the contained field commands you can create a main and a subtit-
le in different founts, change the background colour, make the grid lines disappear,
etc.
Y- Axis
When you click this field, you can define the temperature depiction range, e.g. from
–20° to +60° or –50° to +200°. The unit depends on the thermometer setting, the big-
ger the range, the less exact the depiction.
If you want to close the window "Real- Time Graph", click the "x" at the top on the
right in the menu "Graph".
Below the "screen" with the continuous temperatures (channel 1 to 4) there is a table
that registers the lowest and the highest appearing temperatures of each channel
with time. Stop the measuring writing and the average value AVG can be seen, too.
In that way you can, for example, find out at what time a temperature has changed at
which sensor in which way.
C) Data Logger
If you click this window symbol, you will see two submenus: "Load" to start the data
logger and "Setup" for the alignment of the measuring instrument to the PC (time
synchronous etc.). Click "Load" and there will appear a mix of "Real-Time- Graph", a
"MAX MIN" depiction (below) and a display of "Data Sets" (data records) to the left of
it. Click one of these data records and the contents will be depicted on the screen,
provided that they have been filed. At the bottom you see the maximum value (MAX)