f) Alarm for overloading
If a set limit value is exceeded, the measuring device will sound an alarm every 10 seconds
and “OVERLOAD” will ash in the display. Press any button to stop the alarm. However, the
OVERLOAD” display will continue to ash.
This function cannot only be used for protection of the measuring device or a connected
load but also to signal when the load has exceeded the set limit value during operation.
You do not have to monitor the display all the time.
A power value (W) as well as a current value (A) can be set as limit value.
The function is deactivated if “0” was entered for both limit values.
If both values are programmed (e.g. 1000 W and 2 A), the alarm is activated when the
lower of the two values is exceeded (for the example above, the alarm is activated at
2 A; this corresponds to a power of 460 W for a mains voltage of 230 V/AC).
If you have set the CO
2
emission (see section e) before setting the limit value for overload-
ing, you can proceed directly with the next step.
Otherwise, the set-up mode must be started by pressing the “SET” button (1) for approx.
3 seconds. “ ” will be shown in the top left of the display and “24Hr” (or “12Hr”) appears
in the upper display. Press the “ ” button (5) briey 3x to open the limit value settings for
overload, see next step.
OVERLOAD” appears in the top of the display, the limit value for overload can now be set.
Briey press the “SET” button (1), then “W” ashes in the display.
Toggle the limit value for power (“W” ashes) and current (“A” ashes) with the “ ” (4)
and “ ” (5) button.
Briey press the “SET” (1) button, the rst position of the limit value ashes.
Change the numeric value of the ashing input position with the (4) or (5)
button.
Briey press the “SET” (1) button to activate the next input position.
After conrming the last input position, the display stops ashing.