Voltsoft User Manual Version 2.4 1 Introduction Dear Customer, Welcome to Voltcraft®. Thank you for purchasing this product and we are sure you have made a very good decision. Voltcraft® - in the field of measuring, charging and network technology, this name represents high quality products which perform superbly and which are created by experts employing continuous innovation and improvement.
Voltsoft User Manual Version 2.4 Table of Contents 1 2 3 4 5 6 7 8 Introduction ........................................................................................................ 2 Using this Manual ................................................................................................ 4 Installation .......................................................................................................... 5 3.1 System Requirements .......................................................
Voltsoft User Manual Version 2.4 2 Using this Manual The Voltsoft System (Voltsoft) is integrated control software for controlling different Voltcraft® electronic products. By using Voltsoft, you can manage your Voltcraft® products using only a single piece of software. This manual will explain the usage and workflow of different components of Voltsoft, and also discuss how Voltsoft can control different hardware models.
Voltsoft User Manual Version 2.4 3 Installation 3.1 System Requirements To install Voltsoft, your computer should contain: - Pentium 233-megahertz (MHz) processor or faster - At least 1GB of RAM - At least 2GB of available space on the hard disk - USB 2.0 / 3.
Voltsoft User Manual 3.2 1. 2. Version 2.4 Install Voltsoft Insert the installation CD-ROM in your drive. The menu will be opened automatically (if installation doesn’t start, double-click autorun.exe in your CD-ROM directory). Follow the on-screen instructions.
Voltsoft User Manual Version 2.
Voltsoft User Manual Version 2.4 Step 5: Click “Install”. Installation will begin.
Voltsoft User Manual Version 2.4 Step 6: Click “Finish” to complete the installation 3.3 Migrate existing data If you have an old version of Voltsoft installed, following dialog will be prompt. Click “Yes” if you want to keep existing data or “No” if you want to have an empty database.
Voltsoft User Manual 3.4 Version 2.4 Register Voltsoft Voltsoft has two different versions: Standard and Professional. The professional version contains more features than the standard edition. Standard vs. Professional Standard User Management Email Management General Settings Language Preference Email Template Device Management (Add / Remove) Custom Graph Email Alert Web Interface √ √ √ Professional √ √ √ √ √ √ √ √ √ Voltsoft will be installed by default as the standard version.
Voltsoft User Manual Version 2.4 2. Click Help -> Online Activation 3. 4. Enter a valid license key and the registration information. Enter the proxy server settings if your computer accesses the Internet through a proxy server. Please read and accept our privacy policy and license agreement. Click the “Activate” button to perform online activation. If activation is successful the following message will be displayed: 5. 6. 7.
Voltsoft User Manual Version 2.4 4 Standard Version 4.1 Launch the Voltsoft Windows Client To start the application, please go to Start Menu -> All Programs -> Voltcraft -> Voltsoft Client Main screen of the Voltsoft client is as follows: 1 3 2 1 Main Menu Area 2 Device List Area 3 Device Control Panel Users can access different functions through the main menu. Contains the list of devices which are already registered in the system.
Voltsoft User Manual 4.2 Version 2.4 General Settings To launch this module, please click File->Settings. 1 2 3 4 5 6 1 2 Unit Preference Data Storage 3 Download Data 4 Email Settings Select the measurement unit used in Voltsoft. In order to prevent data overload, the system will delete old data automatically. User can specify the number of days to keep the device readings.
Voltsoft User Manual 5 Web Server Setting Version 2.4 This setting is available in the professional version only. Configure the web server port number for the web-based version of Voltsoft. The local IP address will also be displayed, however, if you have more then one network card, then only the first IP address detected will be shown here. 6 Restart Voltsoft Server Save Close The maximum number of logins controls the maximum number of concurrent logins. Restart the Voltsoft Server.
Voltsoft User Manual 4.3 Version 2.4 Add New Device This module should automatically pop up when the user plugs a new device into the computer. However, to launch this module manually, click Device Management->Add New Device. 1 2 1 Select Device 2 Auto-detect 3 4 Add Close 3 4 To add a new device: 1. Select the device series (only Data Logger available in the current version). 2. Select model number. 3. Enter a unique alias.
Voltsoft User Manual 4.4 Version 2.4 Remove Existing Device This module allows the user to remove devices which are no longer in use. To launch this module, click Device Management->Remove Existing Device. To remove a device, click the device in the list and click the “Remove” button. Click “Remove All” button to remove all devices at the same time.
Voltsoft User Manual 4.5 Version 2.4 Device Control Panel The opened device will be displayed in the device control panel area in tab format. Each tab will contain information for one single device. 1 2 Each device tab contains: 1 Device Menu Area 2 3 Data Tab Graph Tab 3 Each device will contain its own menu, which will be explained in an upcoming section. Display the selected data in list form. Display the selected data in a graphical format.
Voltsoft User Manual Version 2.4 5 Professional Version All features of the standard version and some advanced features are included in the professional version. The following features will be available after online activation of the professional version. 5.1 User Management To launch the user management module, click on File->User Management on the main menu. The user management of this module is only for the web-based version.
Voltsoft User Manual 5.2 Version 2.4 Email Management This module allows the user to manage the email addresses of those who will receive email alerts. To launch this module, click File->Email Management in the main menu. 1 2 1 2 Email Address Add New Email 3 Remove Email 4 Close 3 4 The email address is configured within Voltsoft. Input a new email address and click the Add button to add a new email into the system.
Voltsoft User Manual 5.3 Version 2.4 Email Template To launch this module, click Preference->Email Template. 1 2 3 1 2 Language Message Content Select the language of the email template. Fill in the title and content for the email template which will be sent in the different cases: Case 1: Maximum Alert This email will be sent when a reading is higher than the maximum alarm level. Case 2: Minimum Alert This email will be sent when a reading is lower than the minimum alarm level.
Voltsoft User Manual Version 2.4 Variable The 1 2 3 4 5.4 following labels are defined as variables and will be replaced when sending out. {DEVICE} The device alias {COLUMN} The device reading name {READING} The device reading value {TIME} The time the event happened Email Alert Voltsoft has an email alert feature, which will send out an email to the specified user when the device reading is above or below a certain level.
Voltsoft User Manual 5.5 Version 2.4 Custom Graph Custom Graph allows the user to graph the measurement readings from more than one device. To create a custom graph: 1. Select Device Management->Custom Graph in main menu. 2. Select New to create a new graph or select the previous saved graph. Click OK to continue. 3.
Voltsoft User Manual Version 2.4 4. Then the user needs to: I. Select the data period or real-time data (only specific devices support real-time reading). II. Select the device and measurement column. III. Click Next Step> to continue. IV. For each column, the system will show the data maximum and minimum values for the selected period. V.
Voltsoft User Manual 5.6 Version 2.4 Web Interface 5.6.1 Using the Voltsoft System (Web) Voltsoft also provides a web-based interface for the user to control the device through Internet Explorer (version 7 or 8). To access the Voltsoft Web interface, please open Internet Explorer (I.E.) on your local computer and input http://127.0.0.1 or http://localhost. If you change the port number in General Settings to another port number, then you are required to enter the port number too, e.g. http://127.0.0.
Voltsoft User Manual Version 2.4 After login, you will see a main screen similar to the Windows client. Click on the device entry and you will be prompted to install an ActiveX control issued by CEI Conrad Electronic International (HK) Ltd. Please click Install to install it.
Voltsoft User Manual Version 2.
Voltsoft User Manual Version 2.4 5.6.2 Accessing Voltsoft Web from a Remote Computer Voltsoft Web allows users to control the device information from a remote computer through I.E., just like the remote feature of the IP camera. However, the computer may need some configuration changes in order to allow access to incoming traffic. 1. First, you need to check the IP address of your computer by opening the settings page in the Windows client or check by using command prompt.
Voltsoft User Manual Version 2.4 3. For testing, you can turn off your firewall. Or you can also configure the firewall by allowing an exception. For details, please contact your network administrator. 4. Then you can try to access the Voltsoft Web through another computer on the same network. E.g. in the above case, you should input http://192.168.1.130 in I.E. If you have any problems, please contact your network administrator to check the network connectivity between the two computers. 5.
Voltsoft User Manual Version 2.4 5.6.3 Using the Voltsoft System (Web) The interface of the Web client will be very similar to the Windows-based client. i.
Voltsoft User Manual Version 2.4 ii.
Voltsoft User Manual Version 2.
Voltsoft User Manual Version 2.
Voltsoft User Manual Version 2.4 2) Tab Layout 5.6.4 Limitation in Web Version Although the interface and function of the Web version is very similar to the Windows version, they have some differences as following: 1) The Web version is targeted to those users who are not in front of the computer which is connected to the device; therefore, the “Add and Remove Device” function will not be available in the Web version.
Voltsoft User Manual Version 2.
Voltsoft User Manual 6.1 Version 2.4 DL101T DL101T is a data logger for storing temperature reading. 6.1.1 Add new DL101T When Voltsoft detects a new DL101T attached, the following dialog will be popped up: Click “Yes”, the following dialog will be displayed: Enter a unique alias for this device, click “Add” will add the device into Voltsoft. User may also launch this module by select Device Management->Add New Device in menu. 6.1.
Voltsoft User Manual Version 2.4 6.1.3 DL101T – Device Control Panel The DL101T Device Control Panel contains 1 Device -> Settings 2 Device -> Download Data 3 Device -> Display / Plot Data 4 Graph -> Plot Colour 5 Graph -> Background Colour 6 Graph -> Grid 7 Graph -> Line 8 Graph -> Points Indicator 9 10 11 12 Graph Graph Graph Graph -> -> -> -> Print Save Image As Zoom Out Zoom To Fit follow items in menu: This will launch the setting page of DL101T. Download reading from device.
Voltsoft User Manual Version 2.4 6.1.4 DL101T - Settings 1 Time 2 3 Logger Name Record Start Condition 4 5 6 Sample Points Sample Rate Recording Time 7 LED Flash Cycle 8 9 Enable LED Alert Temperature Low / High Alarm Default Button Setup Button Close Button 10 11 12 Configure the device data time value. The user can specify a defined time or use the system date time. Input the unique alias for that device.
Voltsoft User Manual Version 2.4 6.1.5 DL101T - Download Data This module allows user to download the data from DL101T. Click “OK” button to stop the recording and start downloading. 6.1.6 DL101T – Display / Plot Data This module allows user to select a range for the device readings from the device and display them in the data tab and graph tab. 1 2 3 PC Storage Range Time Range OK 4 Cancel Download all data stored in the database. Select the data reading range.
Voltsoft User Manual Version 2.4 6.1.7 DL101T – Data View DL101T contains one measurement (Temperature) only, its unit can be Celsius or Fahrenheit, depending on the setting in general setting. 1 2 Export Excel Export CSV Export the reading to Excel (.xls) format. Export the reading to Excel (.csv) format.
Voltsoft User Manual Version 2.4 6.1.8 DL101T – Graph View Our graph support following operations 1 2 3 4 Mouse wheel Mouse click and drag Shift + mouse click Mouse over on point Zoom-in / Zoom-Out Zoom-in Pan Display reading values 6.1.9 DL101T – Web Interface Please refer to section 5.6 on how to launch the web interface. The web interface for DL101T is the same as Windows version, except the downloaded data can only have 10,000 readings in a single download.
Voltsoft User Manual 6.2 Version 2.4 DL121TH DL121TH is a data logger for storing temperature and humidity reading. 6.2.1 Add new DL121TH When Voltsoft detected a new DL121TH attached, the following dialog will be popped up: Click “Yes”, the following dialog will be displayed: Enter a unique alias for this device, click “Add” will add the device into Voltsoft. User may also launch this module by selecting Device Management->Add New Device in menu. 6.2.
Voltsoft User Manual Version 2.4 6.2.3 DL121TH – Device Control Panel DL121TH contain follow items in menu: 1 Device -> Settings 2 Device -> Download Data 3 Device -> Display / Plot Data 4 Graph -> Plot Colour 5 Graph -> Background Colour 6 Graph -> Grid 7 Graph -> Line 8 Graph -> Points Indicator 9 10 11 12 Graph Graph Graph Graph -> -> -> -> Print Save Image As Zoom Out Zoom To Fit This will launch the setting page of DL121TH. Download reading from device.
Voltsoft User Manual Version 2.4 6.2.4 DL121TH - Settings 1 Time 2 3 Logger Name Record Start Condition 4 5 6 Sample Points Sample Rate Recording Time 7 LED Flash Cycle 8 9 Enable LED Alert Temperature Low / High Alarm Relative humidity Low / High Alarm Default Button Setup Button Close Button 10 11 12 13 Configure the device data time value. The user can specify a defined time or use the system date time. Input the unique alias for that device.
Voltsoft User Manual Version 2.4 6.2.5 DL121TH - Download Data This module allows user to download the data from DL121TH. Click “OK” button to stop the recording and start downloading. 6.2.6 DL121TH – Display / Plot Data This module allows user to select a range for the device readings from the device and display them in the data tab and graph tab. 1 2 3 PC Storage Range Time Range OK 4 Cancel Download all data stored in the database. Select the data reading range.
Voltsoft User Manual Version 2.4 6.2.7 DL121TH – Data View DL121TH contains three measurements (Temperature, relative humidity and dew point), template / dew point unit can be Celsius or Fahrenheit, depending on the setting in general setting. 1 2 Export Excel Export CSV Export the reading to Excel (.xls) format. Export the reading to Excel (.csv) format.
Voltsoft User Manual Version 2.4 6.2.8 DL121TH – Graph View Our graph supports the following operations 1 2 3 4 Mouse wheel Mouse click and drag Shift + mouse click Mouse over on point Zoom-in / Zoom-Out Zoom-in Pan Display reading values 6.2.9 DL121TH –Web Interface Please refer to section 5.6 on how to launch the web interface. The web interface for DL121TH is the same as Windows version, except the downloaded data can only have 10,000 reading in a single download.
Voltsoft User Manual 6.3 Version 2.4 DL131G DL131G is a data logger for storing vibration reading. time Fast Fourier Transform (FFT) measurement. DL131G supports real time and real 6.3.1 Add new DL131G When Voltsoft detected a new DL131G attached, the following dialog will be popped up: Click “Yes”, following dialog will be displayed: Enter a unique alias for this device, click “Add” will add the device into Voltsoft.
Voltsoft User Manual Version 2.4 6.3.
Voltsoft User Manual Version 2.4 6.3.4 DL131G – Settings 1 Time 2 3 Logger Name Sample Rate 4 LED Flash RateCycle 5 Record Start Condition 6 Motion Detection Threshold Setup 7 Recording Mode 8 9 10 Default Button Setup Button Close Button Configure the device data time value. User can specify a defined time or use the system date time. Input the unique alias for that device. Instruct the data logger to log readings at a specific rate.
Voltsoft User Manual Version 2.4 6.3.5 DL131G - Download Data This module allows user to download the data from DL131G. Click “OK” button to stop the recording and start downloading. 6.3.6 DL131G – Display / Plot Data This module allows user to select a range for the device readings from the device and display them in the data tab and graph tab. 1 2 3 PC Storage Range Time Range Real Time Data 4 5 Real Time FFT OK 6 Cancel Download all data stored in the database. Select the data reading range.
Voltsoft User Manual Version 2.4 6.3.7 DL131G – Data View DL131G contains four measurements (X Value, Y Value, Z Value and Vector Sum). 1 2 Export Excel Export CSV Export the reading to Excel (.xls) format. Export the reading to Excel (.csv) format.
Voltsoft User Manual Version 2.4 6.3.
Voltsoft User Manual Version 2.4 6.3.9 DL131G – Real Time FFT The logger will enter real time FFT mode when select “Real Time FFT” in “Display / Plot Data”. In FFT mode, there is two options for displaying data: Time Domain and Frequency Domain. Time Domain: In time domain mode, total 128 reading will be download at any specific period of time.
Voltsoft User Manual Version 2.4 Frequency Domain: In frequency domain mode, the 128 reading downloaded will be calculate and transform to 256 readings to display.
Voltsoft User Manual 6.4 Version 2.4 DL141TH DL141TH is a data logger for storing temperature and humidity readings. 6.4.1 Add new DL141TH When Voltsoft detected a new DL141TH attached, the following dialog will be popped up: Click “Yes”, the following dialog will be displayed: Enter a unique alias for this device, click “Add” will add the device into Voltsoft. User may also launch this module by selecting Device Management->Add New Device in menu. 6.4.
Voltsoft User Manual Version 2.4 6.4.3 DL141TH – Device Control Panel The DL141TH Device Control Panel contains the following items in menu: 1 Device -> Settings This will launch the setting page of DL141TH. 2 Device -> Download Data Download reading from device. 3 Device -> Display / Plot Data Select the time range that the device reading should be retrieved. 4 Graph -> Plot Colour This will launch the Plot Colour module to change the colour of the individual lines.
Voltsoft User Manual Version 2.4 6.4.4 DL141TH – Settings 1 Device Time 2 3 Logger Name Record Start Condition Sample Rate 5 Recording Time 6 LED Flash Cycle 7 Recording 8 9 Enable LED Alert Temperature Low / High Alarm Humidity Low / High Alarm Default Button Setup Button Close Button 10 11 12 13 Configure the device data time value. User can specify a defined time or use the system date time. Enter the unique alias for that device.
Voltsoft User Manual Version 2.4 6.4.5 DL141TH - Download Data This module allows user to download the data from DL141TH. Click “OK” button to stop the recording and start downloading. 6.4.6 DL141TH – Display / Plot Data This module allows user to select a range for the device readings from the device and display them in the data tab and graph tab. 1 2 3 PC Storage Range Time Range OK 4 Cancel Download all data stored in the database. Select the data reading range.
Voltsoft User Manual Version 2.4 6.4.7 DL141TH – Data View DL141TH contains three measurements (Temperature, relative humidity and dew point), template / dew point unit can be Celsius or Fahrenheit, depending on the setting in general setting. 1 2 Export Excel Export CSV Export the reading to Excel (.xls) format. Export the reading to Excel (.csv) format.
Voltsoft User Manual Version 2.4 6.4.8 DL141TH – Graph View Our graph supports the following operations 1 2 3 4 Mouse wheel Mouse click and drag Shift + mouse click Mouse over on point Zoom-in / Zoom-Out Zoom-in Pan Display reading values 6.4.9 DL141TH – Web Interface Please refer to section 5.6 on how to launch the web interface. The web interface for DL141TH is the same as Windows version, except the downloaded data can only have 10,000 readings in a single download.
Voltsoft User Manual 6.5 Version 2.4 DL161S DL161S is a data logger for storing sound level reading. measurement. DL161S supports real time 6.5.1 Add new DL161S When Voltsoft detected a new DL161S attached, the following dialog will be popped up: Click “Yes”, following dialog will be displayed: Enter a unique alias for this device, click “Add” will add the device into Voltsoft. User may also launch this module by selecting Device Management->Add New Device in menu. 6.5.
Voltsoft User Manual Version 2.4 6.5.
Voltsoft User Manual Version 2.4 6.5.4 DL161S – Settings 1 Time 2 3 4 5 Logger Name Sound Unit Measuring speed Record Start Condition 6 Sample Rate 7 8 Sample Points Infinite 9 Recording Time 10 LED Flash Cycle 11 Logger Mode 12 Storage Setup Configure the device data time value. User can specify a defined time or use the system date time. Input the unique alias for that device. The sound unit can be dBA or dBC. The measuring speed can be Fast or Slow.
Voltsoft User Manual Version 2.4 Real Time – 13 14 LED Flash for High / Low Alarm Low / High Alarm for dBA 15 Low / High Alarm for dBC 16 17 18 Default Button Setup Button Close Button The data will be stored in real time mode. Enable / disable LED flash when the alarm is triggered. Configure the sound level (at unit dBA) for the low / high alarm level. Configure the sound level (at unit dBC) for the low / high alarm level. Load the factory default settings. Save changes. Close this interface. 6.5.
Voltsoft User Manual Version 2.4 6.5.7 DL161S – Data View DL161S contains two measurements (sound level in dBA and sound level in dBC), the device can record only one measurement at any specific unit of time (Control in Setting). 1 2 Export Excel Export CSV Export the reading to Excel (.xls) format. Export the reading to Excel (.csv) format.
Voltsoft User Manual Version 2.4 6.5.
Voltsoft User Manual Version 2.4 6.5.9 DL161S – Email Alert As DL161S supports real time measurement, therefore, it has an email alert feature, which will send out an email to the specified user when the device reading is above or below a certain level. The alert level can be configured in Setting. User can use this module to select who will receive the email for the specific device. 6.5.10 DL161S – Calibration DL161S provides an interface to the user for sound level calibration.
Voltsoft User Manual 6.5.11 Version 2.4 DL161S – Web Interface Please refer to section 5.6 on how to launch the web interface. The web interface for DL161S is the same as Windows version, except the downloaded data can only have 10,000 readings in a single download.
Voltsoft User Manual 6.6 Version 2.4 DL141TH2K DL141TH2K is a data logger for storing light level. 6.6.1 Add new DL141TH2K When Voltsoft detects a new DL141TH2K attached, the following dialog will be popped up: Click “Yes”, the following dialog will be displayed: Enter a unique alias for this device, click “Add” will add the device into Voltsoft. User may also launch this module by select Device Management->Add New Device in menu. 6.6.
Voltsoft User Manual Version 2.4 6.6.3 DL141TH2K– Device Control Panel The DL141TH2K Device Control Panel contains follow items in menu: 1 Device -> Settings This will launch the setting page of DL141TH2K. 2 Device -> Download Data Download reading from device. 3 Device -> Display / Plot Data Select the time range that the device reading should be retrieved. 4 Graph -> Plot Colour This will launch the Plot Colour module to change the colour of the individual lines.
Voltsoft User Manual Version 2.4 6.6.4 DT141TH2K - Settings 1 Time 2 3 Logger Name Record Start Condition 4 5 6 Sample Points Sample Rate Recording Time 7 LED Flash Cycle 8 9 10 11 12 Enable LED Alert Low / High Alarm Default Button Setup Button Close Button Configure the device data time value. The user can specify a defined time or use the system date time. Input the unique alias for that device.
Voltsoft User Manual Version 2.4 6.6.5 DL141TH2K - Download Data This module allows user to download the data from DL141TH2K. Click “OK” button to stop the recording and start downloading. 6.6.6 DL141TH2K– Display / Plot Data This module allows user to select a range for the device readings from the device and display them in the data tab and graph tab. 1 2 3 PC Storage Range Time Range Measurement 4 OK 5 Cancel Download all data stored in the database. Select the data reading range.
Voltsoft User Manual Version 2.4 6.6.7 DL141TH2K – Data View DL141TH2K contains total four measurements:T1, T2, Temperature and Relative humidity. 1 2 Export Excel Export CSV Export the reading to Excel (.xls) format. Export the reading to Excel (.csv) format.
Voltsoft User Manual Version 2.4 6.6.8 DL141TH2K– Graph View Our graph support following operations 1 2 3 4 Mouse wheel Mouse click and drag Shift + mouse click Mouse over on point Zoom-in / Zoom-Out Zoom-in Pan Display reading values 6.6.9 DL141TH2K– Web Interface Please refer to section 5.6 on how to launch the web interface. The web interface for DL141TH2K is the same as Windows version, except the downloaded data can only have 10,000 readings in a single download.
Voltsoft User Manual 6.7 Version 2.4 DL181THP DL181THP is a data logger for storing temperature, humidity and air pressure reading. 6.7.1 Add new DL181THP When Voltsoft detected a new DL181THP attached, the following dialog will be popped up: Click “Yes”, the following dialog will be displayed: Enter a unique alias for this device, click “Add” will add the device into Voltsoft. User may also launch this module by selecting Device Management->Add New Device in menu. 6.7.
Voltsoft User Manual Version 2.4 6.7.3 DL181THP – Device Control Panel The DL181THP Device Control Panel contains the following items in menu: 1 Device -> Settings This will launch the setting page of DL181THP. 2 Device -> Download Data Download reading from device. 3 Device -> Display / Plot Data Select the time range that the device reading should be retrieved. 4 Graph -> Plot Colour This will launch the Plot Colour module to change the colour of the individual lines.
Voltsoft User Manual Version 2.4 6.7.4 DL181THP – Settings 1 Time 2 3 Logger Name Record Start Condition 4 Sample Rate 5 6 Sample Points Recording Time 7 8 Altitude Record LED Flash 9 10 Enable LED Alert Temperature Low / High Alarm Humidity Low / High Alarm Air Pressure Low / High Alarm Default Button Setup Button Close Button 11 12 13 14 15 Configure the device data time value. The user can specify a defined time or use the system date time. Input the unique alias for that device.
Voltsoft User Manual Version 2.4 6.7.5 DL181THP - Download Data This module allows user to download the data from DL181THP. Click “OK” button to stop the recording and start downloading. 6.7.6 DL181THP – Display / Plot Data This module allows user to select a range for the device readings from the device and display them in the data tab and graph tab. 1 2 3 PC Storage Range Time Range OK 4 Cancel Download all data stored in the database. Select the data reading range.
Voltsoft User Manual Version 2.4 6.7.7 DL181THP – Data View DL181THP contains three measurements (Temperature, relative humidity and pressure), template unit can be Celsius or Fahrenheit and pressure unit can be hPa / kPa / Bar / SPI, depending on the setting in general setting. 1 2 Export Excel Export CSV Export the reading to Excel (.xls) format. Export the reading to Excel (.csv) format.
Voltsoft User Manual Version 2.4 6.7.
Voltsoft User Manual Version 2.4 6.7.9 DL181THP – Web Interface Please refer to section 5.6 on how to launch the web interface. The web interface for DL181THP is the same as Windows version, except the downloaded data can only have 10,000 readings in a single download.
Voltsoft User Manual 6.8 Version 2.4 DL131LUX DL131LUX is a data logger for storing light level. 6.8.1 Add new DL131LUX When Voltsoft detects a new DL131LUX attached, the following dialog will be popped up: Click “Yes”, the following dialog will be displayed: Enter a unique alias for this device, click “Add” will add the device into Voltsoft. User may also launch this module by select Device Management->Add New Device in menu. 6.8.
Voltsoft User Manual Version 2.4 6.8.3 DL131LUX – Device Control Panel The DL131LUX Device Control Panel contains follow items in menu: 1 Device -> Settings This will launch the setting page of DL131LUX. 2 Device -> Download Data Download reading from device. 3 Device -> Display / Plot Data Select the time range that the device reading should be retrieved. 4 Graph -> Plot Colour This will launch the Plot Colour module to change the colour of the individual lines.
Voltsoft User Manual Version 2.4 6.8.4 DL131LUX - Settings 1 Time 2 3 Logger Name Record Start Condition 4 5 6 Sample Points Sample Rate Recording Time 7 LED Flash Cycle 8 9 10 11 12 Enable LED Alert Low / High Alarm Default Button Setup Button Close Button Configure the device data time value. The user can specify a defined time or use the system date time. Input the unique alias for that device.
Voltsoft User Manual Version 2.4 6.8.5 DL131LUX - Download Data This module allows user to download the data from DL131LUX. Click “OK” button to stop the recording and start downloading. 6.8.6 DL131LUX – Display / Plot Data This module allows user to select a range for the device readings from the device and display them in the data tab and graph tab. 1 2 3 PC Storage Range Time Range OK 4 Cancel Download all data stored in the database. Select the data reading range.
Voltsoft User Manual Version 2.4 6.8.7 DL131LUX – Data View DL131LUX contains one measurement only, the light level. 1 2 Export Excel Export CSV Export the reading to Excel (.xls) format. Export the reading to Excel (.csv) format.
Voltsoft User Manual Version 2.4 6.8.8 DL131LUX – Graph View Our graph support following operations 1 2 3 4 Mouse wheel Mouse click and drag Shift + mouse click Mouse over on point Zoom-in / Zoom-Out Zoom-in Pan Display reading values 6.8.9 DL131LUX – Web Interface Please refer to section 5.6 on how to launch the web interface. The web interface for DL131LUX is the same as Windows version, except the downloaded data can only have 10,000 readings in a single download.
Voltsoft User Manual 6.9 Version 2.4 DL161SAN DL161SAN is a data logger for storing wind speed. 6.9.1 Add new DL161SAN When Voltsoft detects a new DL161SAN attached, the following dialog will be popped up: Click “Yes”, the following dialog will be displayed: Enter a unique alias for this device, click “Add” will add the device into Voltsoft. User may also launch this module by select Device Management->Add New Device in menu. 6.9.
Voltsoft User Manual Version 2.4 6.9.3 DL161SAN – Device Control Panel The DL161SAN Device Control Panel contains follow items in menu: 1 Device -> Settings This will launch the setting page of DL161SAN. 2 Device -> Download Data Download reading from device. 3 Device -> Display / Plot Data Select the time range that the device reading should be retrieved. 4 Graph -> Plot Colour This will launch the Plot Colour module to change the colour of the individual lines.
Voltsoft User Manual Version 2.4 6.9.4 DL161SAN - Settings 1 Time 2 3 Logger Name Record Start Condition 4 5 6 Sample Points Sample Rate Recording Time 7 LED Flash Cycle 8 9 10 11 12 Enable LED Alert Low / High Alarm Default Button Setup Button Close Button Configure the device data time value. The user can specify a defined time or use the system date time. Input the unique alias for that device.
Voltsoft User Manual Version 2.4 6.9.5 DL161SAN - Download Data This module allows user to download the data from DL161SAN. Click “OK” button to stop the recording and start downloading. *You must place the datalogger on the key lock before download data. 6.9.6 DL161SAN – Display / Plot Data This module allows user to select a range for the device readings from the device and display them in the data tab and graph tab.
Voltsoft User Manual Version 2.4 6.9.7 DL161SAN – Data View DL161SAN contains four measurement: Maximum Value, Average Value, Minimum Value and RT Value. 1 2 Export Excel Export CSV Export the reading to Excel (.xls) format. Export the reading to Excel (.csv) format.
Voltsoft User Manual Version 2.4 6.9.8 DL161SAN – Graph View Our graph support following operations 1 2 3 4 Mouse wheel Mouse click and drag Shift + mouse click Mouse over on point Zoom-in / Zoom-Out Zoom-in Pan Display reading values 6.9.9 DL161SAN – Web Interface Please refer to section 5.6 on how to launch the web interface. The web interface for DL161SAN is the same as Windows version, except the downloaded data can only have 10,000 readings in a single download.
Voltsoft User Manual Version 2.4 6.10 DL201THM DL201THM is a data logger for storing moisture. 6.10.1 Add new DL201THM When Voltsoft detects a new DL201THM attached, the following dialog will be popped up: Click “Yes”, the following dialog will be displayed: Enter a unique alias for this device, click “Add” will add the device into Voltsoft. User may also launch this module by select Device Management->Add New Device in menu. 6.10.
Voltsoft User Manual 6.10.3 Version 2.4 DL201THM – Device Control Panel The DL201THM Device Control Panel contains follow items in menu: 1 Device -> Settings This will launch the setting page of DL201THM. 2 Device -> Download Data Download reading from device. 3 Device -> Display / Plot Data Select the time range that the device reading should be retrieved. 4 Graph -> Plot Colour This will launch the Plot Colour module to change the colour of the individual lines.
Voltsoft User Manual 6.10.4 Version 2.4 DL201THM - Settings 1 Time 2 3 Logger Name Record Start Condition 4 5 6 Sample Points Sample Rate Recording Time 7 LED Flash Cycle 8 9 Enable LED Alert Low / High Alarm 10 11 12 Default Button Setup Button Close Button Configure the device data time value. The user can specify a defined time or use the system date time. Input the unique alias for that device.
Voltsoft User Manual 6.10.5 Version 2.4 DL201THM - Download Data This module allows user to download the data from DL201THM. Click “OK” button to stop the recording and start downloading. 6.10.6 DL201THM – Display / Plot Data This module allows user to select a range for the device readings from the device and display them in the data tab and graph tab. 1 2 3 PC Storage Range Time Range Measurement 4 OK 5 Cancel Download all data stored in the database. Select the data reading range.
Voltsoft User Manual 6.10.7 Version 2.4 DL201THM – Data View DL201THM contains three measurements: Wood humidity, Temperature, Relative humidity. 1 2 Export Excel Export CSV Export the reading to Excel (.xls) format. Export the reading to Excel (.csv) format.
Voltsoft User Manual 6.10.8 Version 2.4 DL201THM – Graph View Our graph support following operations 1 2 3 4 Mouse wheel Mouse click and drag Shift + mouse click Mouse over on point 6.10.9 Zoom-in / Zoom-Out Zoom-in Pan Display reading values DL201THM – Web Interface Please refer to section 5.6 on how to launch the web interface. The web interface for DL201THM is the same as Windows version, except the downloaded data can only have 10,000 readings in a single download.
Voltsoft User Manual Version 2.4 6.11 DL111K DL111K is a data logger for storing temperature reading. 6.11.1 Add new DL111K When Voltsoft detected a new DL111K attached, the following dialog will be popped up: Click “Yes”, the following dialog will be displayed: Enter a unique alias for this device, click “Add” will add the device into Voltsoft. User may also launch this module by selecting Device Management->Add New Device in menu. 6.11.
Voltsoft User Manual 6.11.3 Version 2.4 DL111K – Device Control Panel The DL111K Device Control Panel contains the following items in menu: 1 2 3 Device -> Settings Device -> Download Data Device -> Display / Plot Data 4 Graph -> Plot Colour 5 Graph -> Background Colour 6 Graph -> Grid 7 Graph -> Line 8 Graph -> Points Indicator 9 10 11 12 Graph Graph Graph Graph -> -> -> -> Print Save Image As Zoom Out Zoom To Fit This will launch the setting page of DL111K.
Voltsoft User Manual 6.11.4 DL111K – Settings 1 Time 2 3 Logger Name Record Start Condition 4 Delay Time 5 7 Sample Rate LED Flash Cycle 8 9 Unit Temperature Low / High Alarm Default Button Setup Button Close Button 10 11 12 Version 2.4 Configure the device data time value. The user can specify a defined time or use the system date time. Input the unique alias for that device. By Button – The data logger will start recording only after the user pressed the red button on the device.
Voltsoft User Manual 6.11.5 Version 2.4 DL111K - Download Data This module allows user to download the data from DL111K. Click “OK” button to stop the recording and start downloading. 6.11.6 DL111K – Display / Plot Data This module allows user to select a range for the device readings from the device and display them in the data tab and graph tab. 1 2 3 PC Storage Range Time Range Measurement 4 OK 5 Cancel Download all data stored in the database. Select the data reading range.
Voltsoft User Manual 6.11.7 Version 2.4 DL111K – Data View DL111K contains one measurement (Temperature) only, its unit can be Celsius or Fahrenheit, and can be selected in Display / Plot Data dialog. 1 2 Export Excel Export CSV Export the reading to Excel (.xls) format. Export the reading to Excel (.csv) format.
Voltsoft User Manual 6.11.8 Version 2.4 DL111K – Graph View Our graph supports the following operations 1 2 3 4 Mouse wheel Mouse click and drag Shift + mouse click Mouse over on point 6.11.9 Zoom-in / Zoom-Out Zoom-in Pan Display reading values DL111K – Web Interface Please refer to section 5.6 on how to launch the web interface. The web interface for DL111K is the same as Windows version, except the downloaded data can only have 10,000 readings in a single download.
Voltsoft User Manual Version 2.4 6.12 DL191A DL191A is a data logger for measuring current. 6.12.1 Add new DL191A When Voltsoft detected a new DL191A attached, the following dialog will be popped up: Click “Yes”, the following dialog will be displayed: Enter a unique alias for this device, click “Add” will add the device into Voltsoft. User may also launch this module by selecting Device Management->Add New Device in menu. 6.12.
Voltsoft User Manual 6.12.3 Version 2.4 DL191A – Device Control Panel The DL191A Device Control Panel contains the following items in menu: 1 2 3 Device -> Settings Device -> Download Data Device -> Display / Plot Data 4 Graph -> Plot Colour 5 Graph -> Background Colour 6 Graph -> Grid 7 Graph -> Line 8 Graph -> Points Indicator 9 10 11 12 Graph Graph Graph Graph -> -> -> -> Print Save Image As Zoom Out Zoom To Fit This will launch the setting page of DL191A.
Voltsoft User Manual 6.12.4 Version 2.4 DL191A – Settings 1 Time 2 3 Logger Name Record Start Condition 4 5 Sample Points Sample Rate 6 Record LED Flash 7 8 9 10 11 Enable LED Alert Low / High Alarm Default Button Setup Button Close Button Configure the device data time value. The user can specify a defined time or use the system date time. Input the unique alias for that device. By Button – The data logger will start recording only after the user pressed the red button on the device.
Voltsoft User Manual 6.12.5 Version 2.4 DL191A - Download Data This module allows user to download the data from DL191A. Click “OK” button to stop the recording and start downloading. 6.12.6 DL191A – Display / Plot Data This module allows user to select a range for the device readings from the device and display them in the data tab and graph tab. 1 2 3 PC Storage Range Time Range OK 4 Cancel Download all data stored in the database. Select the data reading range.
Voltsoft User Manual 6.12.7 Version 2.4 DL191A – Data View DL191A contains one measurement (current) only. 1 2 Export Excel Export CSV Export the reading to Excel (.xls) format. Export the reading to Excel (.csv) format.
Voltsoft User Manual 6.12.8 Version 2.4 DL191A – Graph View Our graph supports the following operations 1 2 3 4 Mouse wheel Mouse click and drag Shift + mouse click Mouse over on point 6.12.9 Zoom-in / Zoom-Out Zoom-in Pan Display reading values DL191A – Web Interface Please refer to section 5.6 on how to launch the web interface. The web interface for DL191A is the same as Windows version, except the download data can only have 10,000 readings in a single download.
Voltsoft User Manual Version 2.4 6.13 DL191V DL191V is a data logger for measuring voltage. 6.13.1 Add new DL191V When Voltsoft detected a new DL191V attached, the following dialog will be popped up: Click “Yes”, the following dialog will be displayed: Enter a unique alias for this device, click “Add” will add the device into Voltsoft. User may also launch this module by selecting Device Management->Add New Device in menu. 6.13.
Voltsoft User Manual 6.13.3 Version 2.4 DL191V – Device Control Panel The DL191V Device Control Panel contains the following items in menu: 1 2 3 Device -> Settings Device -> Download Data Device -> Display / Plot Data 4 Graph -> Plot Colour 5 Graph -> Background Colour 6 Graph -> Grid 7 Graph -> Line 8 Graph -> Points Indicator 9 10 11 12 Graph Graph Graph Graph -> -> -> -> Print Save Image As Zoom Out Zoom To Fit This will launch the setting page of DL191V.
Voltsoft User Manual 6.13.4 Version 2.4 DL191V – Settings 1 Time 2 3 Logger Name Record Start Condition 4 5 Sample Points Sample Rate 6 Record LED Flash 7 8 9 10 11 Enable LED Alert Low / High Alarm Default Button Setup Button Close Button Configure the device data time value. The user can specify a defined time or use the system date time. Input the unique alias for that device. By Button – The data logger will start recording only after the user pressed the red button on the device.
Voltsoft User Manual 6.13.5 Version 2.4 DL191V - Download Data This module allows user to download the data from DL191V. Click “OK” button to stop the recording and start downloading. 6.13.6 DL191V – Display / Plot Data This module allows user to select a range for the device readings from the device and display them in the data tab and graph tab. 1 2 3 PC Storage Range Time Range OK 4 Cancel Download all data stored in the database. Select the data reading range.
Voltsoft User Manual 6.13.7 Version 2.4 DL191V – Data View DL191V contains one measurement (voltage) only. 1 2 Export Excel Export CSV Export the reading to Excel (.xls) format. Export the reading to Excel (.csv) format.
Voltsoft User Manual 6.13.8 Version 2.4 DL191V – Graph View Our graph supports the following operations 1 2 3 4 Mouse wheel Mouse click and drag Shift + mouse click Mouse over on point 6.13.9 Zoom-in / Zoom-Out Zoom-in Pan Display reading values DL191V – Web Interface Please refer to section 5.6 on how to launch the web interface. The web interface for DL191V is the same as Windows version, except the downloaded data can only have 10,000 readings in a single download.
Voltsoft User Manual Version 2.4 6.14 DL151AN DL151AN is a data logger for measuring air velocity. 6.14.1 Add new DL151AN When Voltsoft detected a new DL151AN attached, the following dialog will be popped up: Click “Yes”, the following dialog will be displayed: Enter a unique alias for this device, click “Add” will add the device into Voltsoft. User may also launch this module by select Device Management->Add New Device in menu. 6.14.
Voltsoft User Manual 6.14.3 Version 2.4 DL151AN – Device Control Panel The DL151AN Device Control Panel contains the following items in menu: 1 2 3 Device -> Settings Device -> Download Data Device -> Display / Plot Data 4 Graph -> Plot Colour 5 Graph -> Background Colour 6 Graph -> Grid 7 Graph -> Line 8 Graph -> Points Indicator 9 10 11 12 Graph Graph Graph Graph -> -> -> -> Print Save Image As Zoom Out Zoom To Fit This will launch the setting page of DL151AN.
Voltsoft User Manual 6.14.4 Version 2.4 DL151AN – Settings 1 Time 2 3 Logger Name Record Start Condition 4 5 Sample Points Sample Rate 6 Record LED Flash 7 8 9 10 11 Enable LED Alert Low / High Alarm Default Button Setup Button Close Button Configure the device data time value. The user can specify a defined time or use the system date time. Input the unique alias for that device. By Button – The data logger will start recording only after the user presses the red button on the device.
Voltsoft User Manual 6.14.5 Version 2.4 DL151AN - Download Data This module allows user to download the data from DL151AN. Click “OK” button to stop the recording and start downloading. 6.14.6 DL151AN – Display / Plot Data This module allows user to select a range for the device readings from the device and display them in the data tab and graph tab. 1 2 3 4 PC Storage Range Time Range Measurement OK 5 Cancel Download all data stored in the database. Select the data reading range.
Voltsoft User Manual 6.14.7 Version 2.4 DL151AN – Data View DL151AN contains one measurement (air velocity) only, but in different unit (m/s, ft/min, knots, km/h and MPH). 1 2 Export Excel Export CSV Export the reading to Excel (.xls) format. Export the reading to Excel (.csv) format.
Voltsoft User Manual 6.14.8 Version 2.4 DL151AN – Graph View Our graph supports the following operations 1 2 3 4 Mouse wheel Mouse click and drag Shift + mouse click Mouse over on point 6.14.9 Zoom-in / Zoom-Out Zoom-in Pan Display reading values DL151AN – Web Interface Please refer to section 5.6 on how to launch the web interface. The web interface for DL151AN is the same as Windows version, except the downloaded data can only have 10,000 readings in a single download.
Voltsoft User Manual Version 2.4 6.15 DL200T / DL210TH / DL220THP DL200T is a data logger for storing temperature. DL210TH is a data logger for storing temperature and humidity. DL220THP is a data logger for storing temperature, humidity and air pressure reading. 6.15.
Voltsoft User Manual 6.15.3 Version 2.4 DL200T / DL210TH / DL220THP – Device Control Panel The DL200T / DL210TH / DL220THP Device Control Panel contains follow items in menu: 1 Device -> Settings This will launch the setting page of DL200T / DL210TH / DL220THP. 2 Device -> Download Data Download reading from device. 3 Device -> Display / Plot Data Select the time range that the device reading should be retrieved.
Voltsoft User Manual 6.15.4 Version 2.4 DL200T / DL210TH / DL220THP - Settings 1 2 Logger Name Logger ID 2 Record Start Condition Input the unique alias for that device. Logger ID is a four digit identifier. Enter a number between 0000 and 9999 e.g. 0014. "IMMEDIATELY UNTIL MEMORY FULL": Data logger starts recording data immediately until the memory is full. "START UPON KEYPRESS": Data logger starts recording after holding button ENTER pressed for few seconds.
Voltsoft User Manual 4 Stop Style Version 2.4 "CIRCULAR LOGGING": Data logger starts recording immediately and circularly. The newest data overwrites the oldest data. It stops recording/logging once the battery is depleted or “CIRCULAR LOGGING” has been replaced by another “RECORD START CONDITION” during configuration. "NONE": No stop condition is specified. Data logger stops recording based on the "RECORD START CONDITION" setting.
Voltsoft User Manual Version 2.4 "FILE NAME" is empty again. 17 18 19 20 Date Format Time Format Owner Location 21 Report Title 22 User Text 23 24 25 Default Button Create Configuration Button Close Button Press "CLOSE" to save the file name pattern and close this window. Select your prefered date format from menu Select between 12 hour or 24 hour format. Key in the owner’s name. Key in the location’s name e.g. the name of the location where you will record.
Voltsoft User Manual 6.15.5 Version 2.4 DL200T / DL210TH / DL220THP - Download Data This module allows user to download the data from DL200T / DL210TH / DL220THP. Click “OK” button to stop the recording and start downloading. 6.15.6 DL200T / DL210TH / DL220THP – Display / Plot Data This module allows user to select a range for the device readings from the device and display them in the data tab and graph tab.
Voltsoft User Manual 6.15.7 Version 2.4 DL200T / DL210TH / DL220THP – Data View DL200T contain two measurement: Temperature and Pause. DL210TH contain three measurements: Temperature, humidity and Pause. DL220THP contains four measurements: Temperature, humidity, air pressure and Pause. Pause will only have value 0 or 1 to indicate the limit alarm was suspended or not (1 = suspended). 1 2 Export Excel Export CSV Export the reading to Excel (.xls) format. Export the reading to Excel (.csv) format.
Voltsoft User Manual 6.15.8 Version 2.4 DL200T / DL210TH / DL220THP – Graph View Our graph support following operations 1 2 3 4 Mouse wheel Mouse click and drag Shift + mouse click Mouse over on point 6.15.9 Zoom-in / Zoom-Out Zoom-in Pan Display reading values DL200T / DL210TH / DL220THP – Web Interface DL200T, DL210TH and DL220THP are not available for web interface.
Voltsoft User Manual Version 2.4 6.16 PL-125-T2 / PL-125-T4 PL-125-T2 / PL-125-T4 are data loggers for storing temperature reading. PL-125-T2 has two channels while PL-125-T4 has four channels for measurement. 6.16.1 Add new PL-125-T2 / PL-125-T4 When Voltsoft detected a new PL-125-T2 / PL-125-T4 attached, the following dialog will be popped up: Click “Yes”, the following dialog will be displayed: Enter a unique alias for this device, click “Add” will add the device into Voltsoft.
Voltsoft User Manual 6.16.3 Version 2.4 PL-125-T2 / PL-125-T4 – Device Control Panel 6.11.3 PL-125-T2 / PL-125-T4 contain follow items in menu: 1 Device -> Settings This will launch the setting page of PL125-T2 / PL-125-T4. 2 Device -> Download Data Download reading from device. 3 Device -> Display / Plot Data Select the time range that the device reading should be retrieved. 4 Graph -> Plot Colour This will launch the Plot Colour module to change the colour of the individual lines.
Voltsoft User Manual 6.16.4 Version 2.4 PL125-T2 / PL-125-T4 - Settings 1 2 Logger Name Time 3 4 5 6 7 Sample Rate Clear Device Default Button Setup Button Close Button Input the unique alias for that device. Configure the device data time value. The user can specify a defined time or use the system date time. Instruct the logger to log readings at a specific rate. Clear the memory on logger. Reload the factory default settings. Save changes. Close this interface.
Voltsoft User Manual 6.16.5 Version 2.4 PL125-T2 / PL-125-T4 - Download Data This module allows user to download the data from PL125-T2 / PL-125-T4. Click “OK” button to stop the recording and start downloading. 6.16.6 PL125-T2 / PL-125-T4 – Display / Plot Data This module allows user to select a range for the device readings from the device and display them in the data tab and graph tab. 1 2 3 PC Storage Range Time Range Measurement 4 OK 5 Cancel Download all data stored in the database.
Voltsoft User Manual 6.16.7 Version 2.4 PL125-T2 / PL-125-T4 – Data View PL125-T2 / PL-125-T4 are both measuring template. PL125-T2 will have two measurements and PL125-T4 will have four measurements. Template unit can be Celsius or Fahrenheit, depending on the selection in download page. 1 2 Export Excel Export CSV Export the reading to Excel (.xls) format. Export the reading to Excel (.csv) format.
Voltsoft User Manual 6.16.8 Version 2.4 PL125-T2 / PL-125-T4 – Graph View Our graph supports the following operations 1 2 3 4 Mouse wheel Mouse click and drag Shift + mouse click Mouse over on point 6.16.9 Zoom-in / Zoom-Out Zoom-in Pan Display reading values PL125-T2 / PL-125-T4 –Web Interface Please refer to section 5.6 on how to launch the web interface. The web interface for 6.11.
Voltsoft User Manual Version 2.4 6.17 IR 1200-50D IR 1200-50D is a data logger for measuring temperature. 6.17.1 Add new IR 1200-50D When Voltsoft detected a new IR 1200-50D attached, the following dialog will be popped up: Click “Yes”, the following dialog will be displayed: Enter a unique alias for this device, click “Add” will add the device into Voltsoft. User may also launch this module by select Device Management->Add New Device in menu. 6.17.
Voltsoft User Manual 6.17.3 Version 2.4 IR 1200-50D – Device Control Panel The IR 1200-50D Device Control Panel contains the follow items in menu: 1 Device -> Settings This will launch the setting page of IR 1200-50D. 2 Device -> Display / Plot Data Select the time range that the device reading should be retrieved. 3 Graph -> Plot Colour This will launch the Plot Colour module to change the colour of the individual lines.
Voltsoft User Manual 6.17.4 Version 2.4 IR 1200-50D – Settings 1 2 Logger Name Sample Rate 3 4 Setup Button Close Button Input the unique alias for that device. Instruct the data logger to log readings at a specific rate (for real time mode only). Save changes. Close this interface.
Voltsoft User Manual 6.17.5 Version 2.4 IR 1200-50D – Play (Real Time Mode) Click the “Play” button in device control panel will switch IR 1200-50D into real time mode and the button label will become “Stop”, click it again to leave real time mode. In real time mode, pressing the trigger on the device will start sending data to PC, no data will be sent if the trigger is not pressed.
Voltsoft User Manual 6.17.6 Version 2.4 IR 1200-50D – Download Store Data Click the “Download Logger” button in the device control panel will trigger the download data action, and the following dialog will be popped up: Follows the instructions displayed, if success, the dialog will dismiss and data will be displayed.
Voltsoft User Manual 6.17.7 Version 2.4 IR 1200-50D – Display / Plot Data This module allows user to select a range for the device readings from the device and display them in the data tab and graph tab. 1 2 3 4 PC Storage Range Time Range Measurement OK 5 Cancel Download all data stored in the database. Select the data reading range. User can select which measurement unit to download. Click OK to accept the input and display the selected reading in the data and graph tabs. Close this module.
Voltsoft User Manual 6.17.8 Version 2.4 IR 1200-50D – Data View IR 1200-50D contains one measurement (Temperature) only, its unit can be Celsius or Fahrenheit, can be selected in Display / Plot Data dialog. 1 2 3 4 Export Excel Export CSV Play Download Logger Export the reading to Excel (.xls) format. Export the reading to Excel (.csv) format. Enter the real time mode. Download stored data in device.
Voltsoft User Manual 6.17.9 Version 2.4 IR 1200-50D – Graph View Our graph supports the following operations 1 2 3 4 Mouse wheel Mouse click and drag Shift + mouse click Mouse over on point 6.17.10 Zoom-in / Zoom-Out Zoom-in Pan Display reading values IR 1200-50D – Web Interface Please refer to section 5.6 on how to launch the web interface. The web interface for IR 1200-50D is the same as Windows version, except the downloaded data can only have 10,000 readings in a single download.
Voltsoft User Manual Version 2.4 6.18 SL451 SL451 is a data logger for storing sound level reading. SL451 support real time measurement. 6.18.1 Add new SL451 To add SL451 to Voltsoft, first connect SL451 to PC via USB port, press the “SETUP” button on the device until the circle icon (on lower left corner) disappears.
Voltsoft User Manual 6.18.3 Version 2.
Voltsoft User Manual 6.18.4 SL451 – Settings 1 2 Logger Name Sample Rate 3 4 Sample Points Infinite 5 Low / High Alarm for dBA 6 Low / High Alarm for dBC 7 8 9 Default Button Setup Button Close Button 6.18.5 Version 2.4 Input the unique alias for that device. Instruct the data logger to log readings at a specific rate. Configure the data logger sample points. For real time mode only, the download will not stop until the user stopped the download.
Voltsoft User Manual 6.18.6 Version 2.4 SL451 – Display / Plot Data This module allows user to select a range for the device readings from the device and display them in the data tab and graph tab. 1 2 3 PC Storage Range Time Range Real Time Data 4 OK Cancel Download all data stored in the database. Select the data reading range. Download real time data, will only enable if the device in real time mode.
Voltsoft User Manual 6.18.7 Version 2.4 SL451 – Data View SL451 contains two measurements (sound level in dBA and sound level in dBC), the device can record only one measurement at any specific unit of time (by press the “A/C” button on device). 1 2 Export Excel Export CSV Export the reading to Excel (.xls) format. Export the reading to Excel (.csv) format.
Voltsoft User Manual 6.18.8 Version 2.
Voltsoft User Manual 6.18.9 Version 2.4 SL451 – Email Alert As SL451 supports real time measurement, therefore, it has an email alert feature, which will send out an email to the specified user when the device reading is above or below a certain level. The alert level can be configured in Setting. User can use this module to select who will receive the email for the specific device. 6.18.10 SL451 – Web Interface Please refer to section 5.6 on how to launch the web interface.
Voltsoft User Manual Version 2.4 6.19 VC930 / VC950 VC930 / VC950 are DMM devices which measure a number of different measurements. 6.19.1 Add new VC930 / VC950 When Voltsoft detected a new VC930 / VC950 attached, the following dialog will be popped up: Click “Yes”, the following dialog will be displayed: Enter a unique alias for this device, click “Add” will add the device into Voltsoft. User may also launch this module by select Device Management->Add New Device in menu. 6.19.
Voltsoft User Manual 6.19.3 Version 2.
Voltsoft User Manual 6.19.4 Version 2.4 VC930 / VC950 - Download Data This module allows user to download the data from VC930 / VC950. Click “OK” button to stop the recording and start downloading. 6.19.5 VC930 / VC950 – Settings 1 2 3 Logger Name Sample Points Infinite 4 Sample Rate 5 6 7 Alarm Settings* Setup Button Close Button Input the unique alias for that device. Configure the data logger sample points.
Voltsoft User Manual V AC+DC % V AC % Version 2.4 A AC+DC % A AC V DC % A DC % V AC+DC % A AC+DC mV AC - % A AC % mV DC - % A DC % mV AC+DC - % A AC+DC % mV AC oC Temp. - mV DC oC Temp. mV AC+DC oC Temp. % % mV AC % oF Temp. - % mV DC % oF Temp. % mV AC+DC % oF Temp.
Voltsoft User Manual 6.19.6 Version 2.4 VC930 / VC950 – Display / Plot Data This module allows user to select a range for the device readings from the device and display them in the data tab and graph tab. 1 2 3 PC Storage Range Time Range Measurement 4 OK 5 Cancel Download all data stored in the database. Select the data reading range. User can select which measurement record to download. Click OK to accept the input and display the selected reading in the data and graph tabs. Close this module.
Voltsoft User Manual Version 2.4 VC930 / VC950 – Data View 6.19.7 VC930 / VC950 contains many different measurements, you will need to specify which measurement (and unit) to download in “Display / Plot data” dialog. 3 1 2 1 Record / Display Button Use these two buttons to toggle between display and record mode. In display mode, the reading measured by the device will be displayed in the display area.
Voltsoft User Manual 6.19.8 Version 2.
Voltsoft User Manual 6.19.9 Version 2.4 VC930 / VC950 – Web Interface Please refer to section 5.6 on how to launch the web interface. The web interface for VC930 / VC950 is similar to the Windows version, except two points: 1. Downloaded data can only have 10,000 readings in a single download. 2. The status of the “Record” and “Display” button will not be refreshed automatically. A “Refresh” button was therefore added, so click on the button to refresh the button status.
Voltsoft User Manual Version 2.4 6.20 VC880 / VC650BT VC880 / VC650BT are DMM devices which measure a number of different measurements. 6.20.1 Add new VC880 / VC650BT To add VC880 / VC650BT to Voltsoft, first connect the device to PC via USB port, press “REL / PC” button on the device until the PC icon appear.
Voltsoft User Manual 6.20.3 Version 2.
Voltsoft User Manual Version 2.4 VC880 / VC650BT – Settings 6.20.4 1 2 3 Logger Name Sample Points Infinite 4 Sample Rate 5 Skip repeat reading 6 7 8 Alarm Settings* Setup Button Close Button Input the unique alias for that device. Configure the data logger sample points. For real time mode only, the download will not stop until the user stops the download. Instruct the data logger to log readings at a specific rate. System will not record a duplicate reading if this option was checked.
Voltsoft User Manual Version 2.
Voltsoft User Manual 6.20.5 Version 2.4 VC880 / VC650BT – Display / Plot Data This module allows user to select a range for the device readings from the device and display them in the data tab and graph tab. 1 2 3 PC Storage Range Time Range Measurement 4 OK 5 Cancel Download all data stored in the database. Select the data reading range. User can select which measurement record to download. Click OK to accept the input and display the selected reading in the data and graph tabs.
Voltsoft User Manual 6.20.6 Version 2.4 VC880 / VC650BT – Data View VC880 / VC650BT contains many different measurements, you will need to specify which measurement (and unit) to download in “Display / Plot data” dialog. 4 1 2 3 1 Record / Display Button Use these two buttons to toggle between display and record mode. In display mode, the reading measured by the device will be displayed in the display area.
Voltsoft User Manual Version 2.4 Command Button Manual Range Auto Range MAX / MIN / AVG Exit Max NG Beep Light Select Hold REL Pass Beep COMP Value COMP Setting Single Log Series Log Load Comparison Memory Clear Comparison Memory Load Device Memory Clear Device Memory Click to send commands to make device entering the manual range. Click to send commands to make device entering the auto range. Click to send commands to enable maximum, minimum, average function.
Voltsoft User Manual 6.20.7 Version 2.
Voltsoft User Manual 6.20.8 Version 2.4 VC880 / VC650BT – Web Interface Please refer to section 5.6 on how to launch the web interface. The web interface for VC880 / VC650BT is the similar to Windows version, except two points: 1. Downloaded data can only have 10,000 readings in a single download. 2. The status of the “Record” and “Display” button will not be refreshed automatically. A “Refresh” button was therefore added, so click on the button to refresh the button status.
Voltsoft User Manual Version 2.4 6.21 VC890 VC890 is a DMM device which measures a number of different measurements. 6.21.1 Add new VC890 To add VC890 to Voltsoft, first connect the device to PC via USB port, press “REL / PC” button on the device until the PC icon appears. When Voltsoft detected a new VC890 attached, the following dialog will be popped up: Click “Yes”, the following dialog will be displayed: Enter a unique alias for this device, click “Add” will add the device into Voltsoft.
Voltsoft User Manual 6.21.3 Version 2.
Voltsoft User Manual Version 2.4 VC890 – Settings 6.21.4 1 2 3 Logger Name Sample Points Infinite 4 Sample Rate 5 Skip repeat reading 6 7 8 Alarm Settings* Setup Button Close Button Input the unique alias for that device. Configure the data logger sample points. For real time mode only, the download will not stop until the user stopped the download. Instruct the data logger to log readings at a specific rate. System will not record a duplicate reading if this option was checked.
Voltsoft User Manual Version 2.
Voltsoft User Manual 6.21.5 Version 2.4 VC890 – Device Setting Extra settings are available for VC890, the user can launch them via Device -> Device Setting. 1 2 3 4 5 6 7 1 Time 2 Battery 3 Logger Memory 4 Logger data display 5 Auto brightness 6 7 Logger sample rate Auto Power Off Configure the device date time value. The user can specify a defined time or use the system date time. Configure the device current using Alkaline or Lithium battery.
Voltsoft User Manual 6.21.6 Version 2.4 VC890 - Download Data This module allows user to download the storage data from VC890. Click “OK” button to stop the recording and start downloading. 6.21.7 VC890 – Display / Plot Data This module allows user to select a range for the device readings from the device and display them in the data tab and graph tab. 1 2 3 PC Storage Range Time Range Measurement 4 OK 5 Cancel Download all data stored in the database. Select the data reading range.
Voltsoft User Manual 6.21.8 Version 2.4 VC890 – Data View VC890 contains many different measurements, you will need to specify which measurement (and unit) to download in “Display / Plot data” dialog. 4 1 2 3 1 Record / Display Button Use these two buttons to toggle between display and record mode. In display mode, the reading measured by the device will be displayed in the display area.
Voltsoft User Manual MAX / MIN / AVG Exit Max NG Beep Light Select Hold REL Pass Beep COMP Value COMP Setting Single Log Series Log Load Comparison Memory Clear Comparison Memory Load Device Memory Clear Device Memory Version 2.4 auto range. Click to send commands to enable maximum, minimum, average function. Click to send commands to exit maximum, minimum, average function. In the COMP VALUE mode, if failed, click button to turn the alarm on/off.
Voltsoft User Manual 6.21.9 Version 2.
Voltsoft User Manual 6.21.10 Version 2.4 VC890 – Web Interface Please refer to section 5.6 on how to launch the web interface. The web interface for VC890 is similar to Windows version, except two points: 1. Downloaded data can only have 10,000 readings in a single download. 2. The status of the “Record” and “Display” button will not be refreshed automatically. A “Refresh” button was therefore added, so click on the button to refresh the button status.
Voltsoft User Manual Version 2.4 6.22 EL4000 EL4000 is a data logger which measures the power consumption of different electronic devices. 6.22.1 Add new EL4000 As EL4000 will not be physically connected to computer, therefore, to create a new EL4000 in Voltsoft, user is required to select Device Management->Add New Device in menu. Select “EL4000” in device series, “EL4000” in model number, enter a unique device alias and click the “Add” button. 6.22.
Voltsoft User Manual 6.22.3 Version 2.4 EL4000 – Device Control Panel The EL4000 Device Control Panel contains the following items in menu: 1 2 3 Device -> Settings Device -> Download Data Device -> Display / Plot Data 4 Graph -> Plot Colour 5 Graph -> Background Colour 6 Graph -> Grid 7 Graph -> Line 8 Graph -> Points Indicator 9 10 11 12 Graph Graph Graph Graph -> -> -> -> Print Save Image As Zoom Out Zoom To Fit This will launch the setting page of EL4000.
Voltsoft User Manual 6.22.4 Version 2.4 EL4000 – Settings 1 Time 2 3 4 5 6 7 8 9 10 11 12 Date Format Time Format Logger Name Logger ID Currency Tariff 1 Tariff 2 Default Save Button Setup Button Close Button Configure the device data time value. The user can specify a defined time or use the system date time. Select either dd/mm/yyyy or mm/dd/yyyy Select either 24 / 12 hour format. Input the unique alias for that device. Select logger ID, from 0 – 9. Select the currency, for calculation.
Voltsoft User Manual 6.22.5 Version 2.4 EL4000 - Download Data This module allows user to download the storage data from EL4000. To download data, click “…”, select the location of data files, and then click the “Download” button to start downloading. Please note that the logger ID of the data file must be the same of the logger ID configured in setting, otherwise download will not be allowed. 6.22.
Voltsoft User Manual 6.22.7 Version 2.4 EL4000 – Data View EL4000 contains three measurements (Current, Active Power and Apparent Power), 1 2 Export Excel Export CSV Export the reading to Excel (.xls) format. Export the reading to Excel (.csv) format.
Voltsoft User Manual 6.22.8 Version 2.
Voltsoft User Manual 6.22.9 Version 2.4 EL4000 – Calculate User can calculate the price for power consumption by using this module. 1 2 1 2 From / To Price 1 / Price 2 Define the record period Unit price for different time period Click the “Calculate” button to calculate the price. 6.22.10 EL4000 –Web Interface Please refer to section 5.6 on how to launch the web interface.
Voltsoft User Manual Version 2.4 7 Auto Upgrade Voltsoft will perform version checking every time when it starts up, and if there is a new version available, the following dialog box will be displayed: User can click “Yes” to perform an upgrade or “No” to skip the upgrade. In order to enjoy the new features of Voltsoft, it is highly recommended to perform the upgrade. The system will continue to launch once the upgrade is completed.
Voltsoft User Manual Version 2.4 8 Appendix 8.1 Real-Time device list Only the following devices will have real-time features: Family Data Logger DMM DMM Model Number DL131G DL161S SL400 VC 930 / VC950 VC 880 / VC650BT / VC890 Remarks: The speed of data logging (i.e. sample rate) much depends on the capacity of your computer and its performance will be affected when 2 or more sets of real-time devices are running at the same time. 8.
Voltsoft User Manual Version 2.