6.19.7 VC930 / VC950 Data View
VC930 / VC950 contains many different measurements, you will need to specify which
measurement (and unit) to download in “Display / Plot data” dialog.
1
Record / Display
Button
Use these two buttons to toggle between display and record
mode.
In display mode, the reading measured by the device will
be displayed in the display area.
In record mode, the reading measured will not only display
in the display area, but also be stored in the database for
future use.
N.B.
i) If the device is in record mode this means it is also in
display mode.
ii) Stopping the display mode will also stop the record
mode.
2
Display Area
Display the measured value.
3
Back to real time
mode
This button will display when the device is in real time
mode but the interface is not showing real-time data (e.g.
downloading log data / historical data).
Clicking this button can return the interface to display real-
time data.