User manual
Voltsoft User Manual Version 2.4
77
6.7.4 DL181THP – Settings
1
Time
Configure the device data time value.
The user can specify a defined time or use the system
date time.
2
Logger Name
Input the unique alias for that device.
3
Record Start Condition
By Button – The data logger will start recording only
after the user presses the red button on
the device.
After Setup – The data logger will start recording
immediately after setup.
4
Sample Rate
Instruct the data logger to log readings at a specific
rate.
5
Sample Points
Configure the data logger sample points.
6
Recording Time
Calculate the recording time based on the selected
sample points and sample rate.
7
Altitude
Allows user to set the current altitude.
8
Record LED Flash
Configure the LED flash cycle - the longer the time, the
longer the battery life.
9
Enable LED Alert
Enable / disable LED flash when the alarm is triggered.
10
Temperature Low / High
Alarm
Configure the temperature low / high alarm level
11
Humidity Low / High Alarm
Configure the humidity low / high alarm level
12
Air Pressure Low / High
Alarm
Configure the air pressure low / high alarm level
13
Default Button
Load the factory default settings.
14
Setup Button
Save changes.
15
Close Button
Close this interface.