Table Of Contents
- 1.General Safety Requirement
- 2.Safety Terms and Symbols
- 3.Quick start
- 4.Panel Operation
- Channel Setting
- Waveform Setting
- Output the modulated waves
- Hexadecimal frequency shift keying (3FSK)
- Quaternary frequency shift keying (4FSK)
- Binary phase shift keying (BPSK)
- Oscillating keying (OSK)
- Output the sweep frequency (Sweep)
- Output the burst (Burst)
- Counter
- Utility function setting
- Edit the Arbitrary Wave (Edit)
- File system (Store)
- Save/recall instrument settings (Preset)
- Use build-in help (Help)
- 5.Communicate with PC
- 6.Troubleshooting
- 7.Specification
- 8.Appendix
3
.
Quick start
4
power-on parameters; save or read the settings file.
Utility: Set the auxiliary system function
Store: Save/recall arbitrary waveform data
Help: To get context help for any front panel button or menu
softkey, press the button and then press the button for which
you need help.
7
Numerical Keypad
Input the parameter
8
CH2 Button Area
CH2 key: Enter the waveform interface and select the CH2
channel (the backlight of the button lights up). After
selecting, the waveform and parameters of CH2 can be set.
Blue Trigger button: CH2 manual trigger button. In sweep or
burst mode, when the trigger source is selected as “Manual”,
each press of this button will initiate a trigger.
On/Off key: Turns the output of the CH2 channel on or off.
When the output is turned on, the backlight of the button
lights up.
9
CH2 Sync Output
Terminal
When Utility → CH1/2 Set → CH2 Sync turned on, this
terminal outputs a sync signal that matches the current
configuration of CH2.
10
CH2 Output
Termnial
Output CH2 signal
11
CH1
⇌
CH2 Button
Display channel copy menu and menu of frequency
synchronization, amplitude synchronization, phase
alignment, etc.
12
CH1 Output
Terminal
Output CH1 signal
13
CH1 Sync Output
Terminal
When Utility → CH1/2 Set → CH1 Sync turned on, this
terminal outputs a sync signal that matches the current
configuration of CH1.
14
CH1 Button Area
CH1 key: Enter the waveform interface and select the CH1
channel (the backlight of the button lights up). After
selecting, the waveform and parameters of CH1 can be set.
Yellow Trigger button: CH1 manual trigger button. In sweep
or burst mode, when the trigger source is selected as
“Manual”, each press of this button will initiate a trigger.
On/Off key: Turns the output of the CH1 channel on or off.
When the output is turned on, the backlight of the button