4.Panel Operation
34
(1) After pressing the Mod function key, press the Modulation type soft key,
use the knob to select, the modulation type is ASK, press the Enter soft key.
(2) Press to display the waveform and parameters of the current carrier.
You can change the parameters of the carrier. For details, please refer to
Output Sine Wave on page 10. Press or Mod to return to the
modulation mode interface.
(3) Press Source to select the source. If external is selected, connect the
external signal source to the Ext Trig/Burst/Fsk In interface on the rear panel
and skip to step (5). If you select internal, continue with the following steps.
(4) Note: When the source selects external, the slope is set to “positive”, then
the larger of the carrier amplitude and modulation amplitude is output
when the logic is high level, and the carrier amplitude and modulation
amplitude are output when the logic low level is input. The smaller one.
When the slope is "negative", the opposite is true.
(5) Press the ASK Rate softkey to set the ASK rate, which can be set from 2 mHz
to 1 MHz (for internal sources only).
(6) Press the Amplitude softkey to set the amplitude, ie the modulation
amplitude, which can be set from 0 mVpp to 1 Vpp.