User manual

Press the HOLD button to freeze the readings on the display. HOLD will appear on the top part of the 6.
display. Press the HOLD button again to return to the display of real-time temperature readings.
Press the SET button to activate/deactivate the backlight.7.
Press the on/off button to switch the device off. If no button is pressed for 20 minutes, the device 8.
will automatically power off.
The section “Adjusting settings” describes how to deactivate the auto-off function.
Special functions
T1/T2 button
Press once:
Reading of sensor T2 appears on top•
Reading of sensor T1 appears underneath•
Press twice:
Difference between both readings (T1-T2) appears on top•
Reading of sensor T1 appears underneath•
Press three times:
Difference between both readings (T1-T2) appears on top•
Reading of sensor T2 appears underneath•
Press four times: Normal display (T1 top, T2 underneath)•
MAX/MIN button
Press once:
Real-time reading appears on top•
The maximum reading (MAX) of the current measurement process appears •
underneath
Point in time, at which the maximum reading was measured, is displayed at •
lower edge of the display in minutes and seconds (min:sec) or in hours and
minutes (hour:min)
Press twice:
Real-time reading appears on top•
The minimum reading (MIN) of the current measurement process appears •
underneath
Point in time, at which the minimum reading was measured, is displayed at •
lower edge of the display in minutes and seconds (min:sec) or in hours and
minutes (hour:min)
Press three times:
Real-time reading appears on top•
The average reading (AVG) of the current measurement process appears •
underneath
The running total time of the current measurement process is displayed at •
lower edge of the display in minutes and seconds (min:sec) or in hours and
minutes (hour:min)
When in MIN/MAX mode, you can switch between T1, T2 and T1-T2 by pressing the •
T1/T2 button.
Press and hold the MAX/MIN button for approx. two seconds to return to normal display mode.•
Adjusting settings
Press and hold the SET button for approx. two seconds. SETUP will appear on the top left corner of 1.
the display. TYPE will appear on the bottom left corner.
Press the ENTER button to select the temperature sensor type.2.
Using the HOLD or MAX/MIN buttons, you can switch between types K and J. Conrm your3.
selection by pressing the ENTER button. The display will show SLP.
Press the ENTER button to activate/deactivate the auto-off function.4.
Using the HOLD or MAX/MIN buttons, you can switch between SLP ON (auto-off function on, clock 5.
symbol appears top-right in display) and SLP OFF (auto-off function off, clock symbol no longer
displayed).ConrmyourselectionbypressingtheENTERbutton.ThedisplaywillshowT1.
Press the ENTER button to compensate any deviation (OFFSET) in measurement accuracy of 6.
sensor T1.
Press the HOLD or MAX/MIN buttons to set any deviation adjustment (± 5 ºC; ± 9 ºF/K). The 7.
displayedreadingchangesaccordingly.ConrmyourselectionbypressingtheENTERbutton.The
display will show T2.
Proceed as described above to compensate a deviation in measurement accuracy of sensor T2.8.
Youcanndfurtherdetailsinthesection“Determiningdeviationofasensor’smeasurement
accuracy”.
To return to the normal display mode, press and hold the SET button for approx. two seconds.9.
Ifyouonlywanttomakeaspecicadjustment,pressandholdtheSETbuttonandselect
the required point using the HOLD or MAX/MIN button. Then press the ENTER button and
make the adjustment.
Determining deviation of a sensor’s measurement accuracy
Turn the thermometer on and place the relevant sensor in an optional temperature calibrator or in 1.
any other reference location with a known and stable temperature.
Wait until the thermometer’s display has stabilised.2.
If there is a difference, you can manually compensate it (see section “Adjusting settings”).3.
MAINTENANCE AND CLEANING7.
No maintenance is necessary for the device apart for occasional cleaning and the changing of the •
battery.
Clean the exterior of the device with a soft, dry cloth or brush only.•
Never use aggressive or chemical cleaning agents, since this might damage the surface of the •
housing or impair operation.
DISPOSAL8.
General
In order to preserve, protect and improve the quality of environment, protect human health
and utilise natural resources prudently and rationally, the user should return unserviceable
product to relevant facilities in accordance with statutory regulations.
The crossed-out wheeled bin indicates the product needs to be disposed separately and
not as municipal waste.
Batteries / rechargeable batteries
The user is legally obliged (battery regulation) to return used batteries and rechargeable
batteries. Disposing used batteries in the household waste is prohibited! Batteries/
rechargeable batteries containing hazardous substances are marked with the crossed-out
wheeled bin. The symbol indicates that the product is forbidden to be disposed via the
domestic refuse. The chemical symbols for the respective hazardous substances are Cd =
Cadmium, Hg = Mercury, Pb = Lead.
You can return used batteries/ rechargeable batteries free of charge to any collecting point of
your local authority, our stores or where batteries/ rechargeable batteries are sold.
Consequently you comply with your legal obligations and contribute to environmental protection!
TECHNICAL DATA9.
Operating voltage: 3 x 1.5 V/DC battery (type AAA)
Max. current consumption: approx. 7 mA
Measuring range:
-200 ºC to +1372 ºC / -328 ºF to +2501 ºF (K type)
-210 ºC to +1100 ºC / -346 ºF to +2012 ºF (J type)
Accuracy:
± 0.15 % + 1 ºC / 1.8 ºF (> -100 ºC / -148 ºF)
± 0.5 % + 2 ºC / 3.6 ºF (< -100 ºC / -148 ºF)
± 0.5 % + 1 ºC / 1.8 ºF (T1-T2)
Temperature sensor measuring range
(included):
-20 ºC to +250 ºC / -4 ºF to +482 ºF
Resolution:
0.1 ºC/ºF/K (< 1000)
1ºC/ºF/K(≥1000)
Operating temperature: 0 ºC to +50 ºC / +32 ºF to +122 ºF
Operating humidity:
max. 80 % (< 31 ºC / 87 ºF)
linearlydecreasingto50%(≥40ºC/104ºF)
Storage temperature: -10 ºC to +50 ºC / +14 ºF to +122 ºF
Storage humidity: < 80 %
Dimensions (W x H x D): 62 x 28 x 162 mm
Weight: 184 g
These operating instructions are published by Voltcraft®,
Lindenweg 15, D-92242 Hirschau/ Germany, Phone +49 180 586 582 7.
Allrightsincludingtranslationreserved.Reproductionbyanymethod,e.g.photocopy,microlming,orthe
capture in electronic data processing systems require the prior written approval by the editor. Reprinting,
also in part, is prohibited.
Theoperatinginstructionsreectthecurrenttechnicalspecicationsattimeofprint.
Wereservetherighttochangethetechnicalorphysicalspecications.
© Copyright 2011 by Voltcraft®.
V2_0911_02-SB