Datasheet
Input command:
GOVP[CR]
Return value:
<voltage>[CR]
OK[CR]
Get preset upper limit of
output Voltage
<voltage>=???
Input command:
GOVP[CR]
Return value:
111[CR]
OK[CR]
Meaning:
The preset upper limit of
output Voltage is 11.1V
Input command:
SOVP<voltage>[CR]
Return value:
OK[CR]
Preset upper limit of
output Voltage
<voltage>=010<???<Max-Volt
*Max-Volt value refer to
product specification
Input command:
SOVP151[CR]
Return value:
OK[CR]
Meaning:
Preset upper limit of output
Voltage as 15.1V
Input command:
GOCP[CR]
Return value:
<current>[CR]
OK[CR]
Get preset upper limit of
output Current
<current>=???
Input command:
GOCP[CR]
Return value:
110[CR]
OK[CR]
Meaning:
The preset upper limit of
output Voltage is 1.1A
Input command:
SOCP<current>[CR]
Return value:
OK[CR]
Preset upper limit of
output Current
<current>=000<???<Max-Curr
*Max-Curr value refer to
product specification
Input command:
SOCP150[CR]
Return value:
OK[CR]
Meaning:
Preset upper limit of output
Voltage as 1.5A