User manual

27
c) Connection to a Direct Voltage Source
• Donotwearanymetalorconductivematerials,suchasjewellery(necklaces,bracelets,rings,etc.).A
shortcircuitattherechargeablebatteryorinvertercausesadangerofinjury,reandexplosion.
• Foraconverterwithpoleterminals,asuitableconnectioncablewithasufcientlylargelinecross-sec-
tionmustbeused(seechapter"TechnicalData").Thelongertheconnectioncable,thelargertheline
cross-section has to be. If the line cross-section is too small, the connection cable may grow hot. There
isadangerofre!Keeptheconnectioncablebetweentheconverterandtherechargeablebatteryas
short as possible for this reason.
Very strong overheating may also cause a defect to the insulation of the connection cable, which may
causeshortcircuit.Thereisariskofexplosionoftherechargeablebattery,aswellasdangerofre!
 Aconverterwithpoleterminalsshouldneverbedirectlyconnectedtoadirectvoltagesource(e.g.acar
battery), but only via an accordingly sized fuse. This fuse should be placed as close as possible to the
direct voltage source.
• Ataconverterwithcigarettelighterplug(types"SW-100"and"SW-150"),theconnectioncablemust
not be cut off, shortened or extended.
• Beforetheinverterisconnectedtothedirectvoltagesource,itmustbeswitchedoff.
• Alwaysobservethecorrectpolarity(plus/+andminus/-)forconnectionoftheconverter.
• Dependingonthepowertakenfromtheinverter,thedirectvoltagesource(e.g.acarbattery)mustbe
able to supply the corresponding current strength.
 • Checkallconnectionsfortighttandgoodelectricalcontactatregularintervals.Hightransferresist-
ancesnotonlyreducetheperformanceoftheinverterbutalsomaycauseoverheatingandre.
• Theinvertermustnotbeconnectedtoelectricalsystems(e.g.amotorvehicle)wherethepluspoleis
grounded or connected to the chassis of the vehicle.
d) Mains Voltage Output
• Donotpullthemainsplugfromthemainssocketoftheinverterbypullingthecable.
• Neverconnecttheoutputoftheinvertertoanother230Vsource(e.g.amainssocket).Theinverter
must not be used to feed mains voltage into an electrical building installation.
• Inthedeactivatedcondition,thechargedcapacitorsmaystillcausethealternatingvoltagetobe
pending at the mains sockets of the converter.
e) Operation
• Donotoperatetheinverterunsupervised.
• Nevertouchtheblanklivecontactsorconnectionterminalsontheinputsideoftheconverter.
• Evenaftertriggeringtheinternalprotectivedeviceordeviceprotection,partsoftheconvertermaystill
be live!
• Thehousingoftheinverterwillheatupinoperation(dependingontheoutput).Therefore,always
observesufcientventilationoftheinverter;nevercoveritinoperation.Neverclosetheventilationslots
of the inverter.
Keep a minimum distance of 10 cm from other devices around the housing of the inverter.