b) Earthing
Observe:
Thissectiondoesnotapplytotheconverter"SW-100"(itemno.511700),sinceitonlyhasaEurosocket.
Connect only a device with protection class II to it.
WhenconnectingdevicesofprotectionclassI(deviceswithprotectivegroundplugorPEconnection),theearthing
of the converter output can be performed via the minus connection of the converter or rechargeable battery. For the
converter"SW-150",ascrewconnectionseparatelyplacedatthehousing(markedwithearthingsymbol)canbe
used.
ObservethatthemetalpartsofthehousingandthePEconnectionoftheprotectivegroundsocketareconnected
internallytotheminusterminal("-")oftherechargeablebatteryconnection.Thezeroconductorconnectiononthe
output side must never be earthed.
Ifanearthingline(green/yellowcable)isused,itmusthaveacross-sectionofatleast6mm²;keepthecableas
short as possible.