Start-up
Do not operate any devices connected to the converter while driving.
After connection to the battery, you may commission the DC-AC converter.
Connect a consumer with suitable rated output to the output socket (13).
Switch on the converter with the operating switch (11). Switch position “1” (On) If the connection is cor-
rect, the two displays (9) and (10) light up now and indicate correct operation.
LED indicator lamps
The green LED indicator lamps 9 (DC input) and 10 (AC output) supply important information about the
converter’s operating state. The two LEDs are working independently of each other. This means that any
interference in the DC input area directly influences the function of the AC output and that an interference
of the output area directly influences the input function.
Operating mode/interference displays LED 9 (DC input) LED 10 (AC output)
Device is switched on and ready for operation. Is lit Is lit
Preliminary warning for deep discharge Flashing slowly Is lit
protection
Switch-off due to deep discharge protection Flashing quickly Flashing quickly
Overvoltage at input Flashing quickly Flashing quickly
Short circuit or overload at the output Flashing quickly Flashing quickly
Standby Operation
In StandBy operation, the converter was switched off and verifies that a load > 10 watt is present at the
output at intervals of approx. 20 s. This reduces internal power consumption and relieves the connected
DC power source.
If a load >10 watt is recognised, the output switches to normal operation. When the consumer was swit-
ched off, the converter automatically goes back to StandBy mode.
To activate this mode, put the small switch no. 2 to “ON” at the DIP switch (4). The
switch points downwards.
To switch off this function, put the small switch no. 2 upwards. The converter is in
continuous operation again.