User manual

37
SWD-300/24 SWD-600/24 SWD-1200/24 SWD-2000/24
INPUT
Nominal input voltage 24 V/DC 24 V/DC 24 V/DC 24 V/DC
Input voltage range 22 - 30 V/DC 22 - 30 V/DC 22 - 30 V/DC 22 - 30 V/DC
Max. input current 15.5 A 31 A 62 A 124 A
Switch-off due to deep discharge 21.0 V idle 21.0 V idle 21.0 V idle 21.0 V idle
protection (factory settings) 19.0 V rated load 19.0 V rated load 19.0 V rated load 19.0 V rated load
Setting area deep discharge 18.0 - 23.0 V 18.0 - 23.0 V 18.0 - 23.0 V 18.0 - 23.0 V
protection
Preliminary warning deep 1.0 V above 1.0 V above 1.0 V above 1.0 V above
discharge protection) switch-off Switch-off Switch-off Switch-off
Reactivation voltage 25 V 25 V 25 V 25 V
Switch-off overvoltage 32 V 32 V 32 V 32 V
Power consumption idle 4 VA 5 VA 9 VA 13 VA
Power consumption StandBy 0.4 VA 0.5 VA 0.9 VA 1.3 VA
OUTPUT
Output voltage 230 V ± 2% 230 V ± 2% 230 V ± 2% 230 V ± 2%
Output frequency 50 Hz ± 1% 50 Hz ± 1% 50 Hz ± 1% 50 Hz ± 1%
Permanent output current 1.3 A effective 2.6 A effective 5.2 A effective 8.7 A effective
Permanent output power 300 VA 600 VA 1200 VA 2000 VA
(cos-phi >0.8)
Peak output power 600 VA 1200 VA 2400 VA 4000 VA
max. 2s (cos-phi >0.8)
Degree of effectiveness Type 90% Type 90% Type 90% Type 90%
Standby switch-off level Output current Output current Output current Output current
<0.1 A <0.2 A <0.3 A <0.4 A
Standby switch-on level >10 W >10 W >10 W >10 W
Power plug 1x protective 1x protective 1x protective 1x protective
contact contact contact contact
GENERAL
USB output type A 5 V/DC 500 mA 5 V/DC 500 mA 5 V/DC 500 mA 5 V/DC 500 mA
Operating temperature -25 to +60°C -25 to +60°C -25 to +60°C -25 to +60°C
(to 66% rated load)
Operating temperature -25 to +40°C -25 to +40°C -25 to +40°C -25 to +40°C
(to 100% rated load)
Dimensions (LxWxH) mm 263x164x88 277x234x88 391x234x88 391x234x88
Weight 1.8 kg 2.9 kg 3.5 kg 4.8 kg