16. VARIOUS BASIC SETTINGS („USER SET“)
In the main menu, select the „USER“ menu with the „BATT TYPE/STOP“ button.
Press the button „START/ENTER“; the display shows the following, for example:
Here you can select one of the three lithium battery types the charger is able to work
with („LiPo“, „LiIon“, „LiFe“).
Briefly push the „START/ENTER“ button. The voltage value then begins to flash.
With the buttons „INC“ or „DEC“, you can select the cell voltage „3.3“, „3.6“ or „3.7“.
At the same time, the corresponding battery type changes in the top line.
Confirm the selection of the lithium battery type with the button „START/ENTER“, and the
voltage value will stop flashing.
¼
The settings made here for the lithium battery type then applies for ALL other
functions, e.g. charging, discharging, etc., see chapter 11.
With the button „INC“, switch to the next setting (or to the previous one with the button
„DEC“).
Here you can set the time in which the charger checks a connected lithium battery for
the correct cell count and terminates the charge process, if applicable.
This may be especially helpful with deep discharged batteries. For a battery with a
higher capacity set a longer time; for one with a lower capacity set a correspondingly
shorter time.
Briefly push the „START/ENTER“ button. The time then begins to flash. With the buttons
„INC“ or „DEC“, you can select the time (5....250 minutes). Save the setting with the
„START/ENTER“ button, the time stops flashing.
USER SET
PROGRAM->
LiFe
V.Type 3.3V
LiPo/LiIo/LiFe
CHK Time 10min