Instructions
41
a) DC voltage (V )
Range Accuracy Resolution
4.000 V
±(0.8 % reading +8 digits)
1 mV
40.00 V 10 mV
400.0 V 100 mV
600 V 1 V
Overload protection: 600 V
Input impedance: approx. 10 MΩ
b) AC voltage (V~)
Range Accuracy Resolution
400.0 mV ±(2.0 % reading +10 digits) 0.1 mV
4.000 V
±(1.6 % reading +4 digits)
1 mV
40.00 V 10 mV
400.0 V 100 mV
600 V 1 V
Overload protection: 600 V
Input impedance: approx. 4.5 MΩ
Frequency response: 45 – 400 Hz
Display: Sine wave valid value (average value response)
c) DC current (A )
Range Accuracy Resolution
µA
400 µA
±(1.3 % reading +3 digits)
0.1 µA
4000 µA 1 µA
mA
40.00 mA
±(1.6 % reading +2 digits)
10 µA
400.0 mA 0.1 mA
A
4.000 A
±(2.0 % reading +10 digits)
1 mA
10.0 A 10 mA
Overload protection:
mAμA range: F1 fuse 6 x 32 mm F 0.5 A H 600 V (CE) Item no.: 702632
10A range: F2 fuse 6 x 25 mm F 10 A H 600 V (CE) Item no.: 700161
Measuring operations of >5 A may only be performed for at most 10 seconds with a subsequent
measuring pause of 15 minutes.