Instructions

4.Advanced User Guidebook
80
4. Under the status of stop, data comparing will stop, and when it goes on running,
the number of Pass/Fail will increase from the former number, not from zero.
5. When the waveform playback mode is on, Pass/Fail is used to test the
played-back waveform specially.
Output
Push the Utility button, select Function in the bottom menu, select Output in the left
menu.
Output menu item in the bottom menu sets the output type of Trig Out(P/F) port in
Figure 3-3 Rear Panel on P6. In the bottom menu, select Output. The description of
Output menu is shown as the follows:
Device and Print Setup menu items set the print output, refer to "How to Print the
Screen Image" on page 93.
LAN Set
Using the LAN port, the oscilloscope can be connected with a computer.
Update
Use the front-panel USB port to update your instrument firmware using a USB
memory device. Refer to "How to Update your Instrument Firmware" on page 80.
DAQ
You can use the multimeter data recorder to record the measurements when
measuring current/voltage by multimeter (optional). Refer to "Multimeter Recorder"
on page 107.
FRA (Frequency Response Analysis)
If there is a built-in arbitrary function generator (optional), you can use the frequency
response analysis. Refer to "Frequency Response Analysis" on page 101.
How to Update your Instrument Firmware
Use the front-panel USB port to update your instrument firmware using a USB
Function
Menu
Setting Description
Type
Trig level
Output trig signal synchronously
Pass/fail
Output High Level when Pass , and Low Level when Fail
AG
Output
CH2 Output of dual-channel waveform generator
(optional)