To Set the System
Language Setting
Press Utility and choose System, press F1 to switch display languages.
Power On Setting
(1) Press Utility and choose System, press F2 to select Power On.
(2) Press F2 to switch between Default/Last. Default means that all the settings
return to default when powered. Last means that all the settings return to the last
one when powered.
To Return to Default Setting
Press Utility and choose System, press F3 to select Set to Default, press F1 to
confirm. All the settings will be set to default. The default settings of the system are as
follows:
Output Default
Function Sine Wave
Frequency 1 kHz
Amplitude/Offset 1 V
p-p
/ 0 Vdc
Waveforms Default
Frequency 1 kHz
Amplitude
1 V
p-p
Offset
0 Vdc
Duty Cycle of Square 50%
Symmetry of Ramp 50%
Pulse Width of Pulse 200 us
Duty Cycle of Pulse 20%
Modulation Default
Modulation waveform
100 Hz, Sine Wave (except FSK)
100 Hz, Square Wave (FSK)
AM Depth 100
FM Deviation 100 Hz
PM Phase Deviation
PWM deviation 0.0%
FSK Hop Frequency 100 Hz