User manual

30
Individual operation
In individual mode, you can connect and adjust both outputs independently of each other. This function
allows operation with 2 different output voltages.
Disconnect consumers connected to outputs A and B.
Switch on the mains power unit at the power switch (1). The operating display (2) lights up and the cur-
rent and voltage display appears on the display.
Press the selection switch “individual” (8). The red indicator above the switch is lit. Outputs A and B can
be adjusted separately.
Set the parameters according to your specifications as described in the chapter “Commissioning”.
Verify again that the output voltage has been set correctly.
Connect the positive terminal (+) of the consumer with the red socket “+” and the negative terminal (-) of
the consumer with the blue socket “-” of the respective output (A/B).
Now you can switch on the connected consumer.
The current consumption of the connected consumer is displayed in Ampere (A) in the power display.
Parallel operation
In parallel mode, you can use the outputs A and B to double the current. In this mode, the outputs A and
B are switched parallel internally. No external switching is required for up to 10 A.
Disconnect consumers connected to outputs A and B.
Switch on the mains power unit at the power switch (1). The operating display (2) lights up and the cur-
rent and voltage display appears on the display.
Press the selection switch “parallel” (7). The red indicator above the switch is lit.
Set the parameters according to your specifications as described in the chapter “Commissioning”. The
voltage settings are made only through output A (master). The current control for output B is deactivated
The current settings are made in combination with outputs A and B. The sum of both current indicators
equals the output current.
Verify again that the output voltage has been set correctly.