4 Troubleshooting
4.1 Common problems
For troubleshooting, check and resolve the following issues as
needed. Contact the factory for assistance if necessary (see
Section 1.2, Where to obtain service, page 1).
If the pump fails to prime:
The priming chamber might be empty or not sufficiently full
Liquid in priming chamber might be overheated
The direction of rotation might be reversed
Rotation speed might be too slow
The impeller or volute might be worn or broken
Delivery line might be under pressure
There could be air leaks in the suction-line or at joints in the line,
loose screws at joints in the line, or broken hoses in the line
There could be an air leak through a damaged mechanical seal
Quick-coupling gaskets might be broken or improperly mounted
Hose clamps might be loose or broken
If capacity is low:
The suction strainer might be clogged
The suction or delivery line might be obstructed
There could be high-friction losses in the suction line, which may
require eliminating bends in the line or restrictions from valves
The suction lift could be too high
The rotation speed might be too slow
The impeller might be clogged