MODEL: PM-2000PBR Warning: This manual contains important safety and operating instruction. Please read it carefully before use the unit.
Specifications: Item PM-2000PBR Rated input Voltage 12VDC 24VDC Continuous Power 2000W 2000W Peak Power 4000W 4000W 9.8~16VDC 19.6~32VDC Input Voltage Range Over Voltage Shutdown 16VDC 32VDC Low Voltage Shutdown 9.8VDC 19.6VDC 10.1VDC 20.
13. Failure guidelines 1. Do not use when the battery is charging. 2. Check the rated voltage of the battery and make sure that it is in the allowable range of the input voltage. No output voltage, buzzer sounds continuously Cut off the load and let it cool naturally for 10 to 30 minutes. Restart it after it resumes to normal temperature. The load power is too large, reduce the total load power to the range of rated power. Avoid blocking the vent and improve the ventilation condition.
(2. AC Output side) 1) When the LCD shows "LO", it indicates that it is currently under-voltage protection. 2) When the LCD shows "HI", it indicates that it is in the state of over-voltage protection. 3) When the LCD shows "OL", it indicates that it is in the state of output overload or short circuit protection. 4) When the LCD shows "OH", it indicates that it is in the state of overheating protection.
Notice: Before use the USB power supply, please make sure the device can be charged by USB and the maximum working current is no more than 2.4A 9. SOFT START TECHNOLOGY The soft start technology built into this inverter protects the unit from delivering too much AC power at once by gradually increasing the AC voltage pushed out. To make sure that you are utilizing this feature, turn on the appliance being used before turning on the inverter.
4.5mm FAULT POWER Battery Status 3. Each outlet of the inverter has a given current rating of the manufacturer. It shall not exceed this value during use. Otherwise, the socket may be damaged by overheating and may cause an electric shock.
Notice: 1. The above table is only for your reference. In practice, the thick wire can be replaced by two thin parallel wires if only the total section acreage of the wire meets the requirements. 2. In high current, the input DC wire may produce voltage drop, therefore,the operating voltage should be subject to the value on the terminals. If the voltage drop is too large, it can increase the acreage of the section or reduce the length of the lead. 3.