Operator`s manual

OPERATION
346
The engine shut-down system will automatically derate or stop the
engine when one or more of the systems listed below reaches a critical
stage:
High Coolant Temperature
Low Oil Pressure
Low Coolant Level
High Crankcase Pressure
High Diesel Particulate Filter Soot Level
Derate and shut-down functions may be applied differently, or added to,
depending on the engine manufacturer. See the engine operator's
manual for more information.
When the shut-down is activated, the tell-tales come on and the buzzer
is also activated. From that time it will take 30 seconds before the
engine shuts down. In this time period, find a safe place to pull off of
the road.
After the engine has been shut down by the system, the override will
allow a restart of the engine for 30 seconds. This is so the vehicle may
be pulled off the road, if necessary. The alarm will remain activated
until repairs have been made to correct the problem.
The operator should not continually override the system as this can
cause serious damage to the vehicle's engine.
vn-vhd.bk Page 346 Tuesday, July 1, 2008 9:44 AM