Reposition or shield any parts that would be damaged by high
temperatures during welding.
Complete the battery cable removal by removing the positive cable
last.
Attach the welder ground cable as close to the weld area as
possible (6 inches or less from the place being welded).
DO NOT connect the welder ground cable near any electronic
module, such as the EECU or its cooling plate.
Welding cables should not be allowed to lie on, or run parallel
with any wiring.
Welding cables should not be allowed to lie near any electronic
component during welding.
After welding is complete and the welded areas have cooled,
inspect wiring and components for possible shorts, nicks,
abrasion or other damage.