User Manual
 DIGITAL MUSIC CORPORATION 11 
However, if the GCX status LED is ON when you want it OFF, you can reverse polarity 
by selecting normally closed. 
For example, let's say you're controlling reverb on your amp from its footswitch input, 
but the GCX status LED is ON when the reverb is OFF. You can fix this by changing 
from normally open to normally closed (plug into the 
SEND/N.C. jack). The LED will 
now show the correct state of the reverb. 
Momentary Type 
Some devices require momentary type switches. A momentary switch changes state 
(from ON to OFF or from OFF to ON) by closing for a short time and then opening 
again. These are most often used for bypass switches on digital effects. 
To use a GCX loop as a momentary switch, connect the GCX loop 
OUT/N.O. jack to the 
footswitch input jack. You must also configure the loop as a momentary switch in the 
Ground Control setup. 