Installation manual

7. DTV Applications DCR 6024/6128/6000
7 – 4
Planning and Installation – Rev. 1 / 7. 2001
7.4 PARAMETER SHEET BVE 9000
For each DCR 6024 connected to the editor BVE 9000 the following parameters
have to be set for the according VTR-port (SETUP/IDC/MACHINE PARAMETER
GROUP) at the initial installation.
It is recommended to install these parameters at all ports to ensure correct
machine control on all ports if other configurations are used (e.g. RS-422 router).
BLOCK BYTE Name Value Remarks
1
1
2
DEV-TYPE
01 / 00H
EOH
DCR 6024 identification
01H at 50 Hz
00H at 60 Hz
1
3
4
MIN PREROLL
TIME
00H
64H / 78H 64H at 50H
78H at 60H
1 5 EDIT DELAY 05H
1 6 EE DELAY 05H
1 7 OVERRUN 05H
1 8 TRAJECTORY CON. 1FH
2 1 TC READ DELAY 0FH
2 2 START DELAY 07H
2 3 AFTER SYNC DEL– FFH
2 4 AFTER SYNC DEL+ 00H
2 5 CONST 11 01H
2 6 CONST 12 64H
2 7 PREROLL SPEED FFH
2 8 QUICK PVW PR TIME 4BH / 5AH 4BH at 50 Hz
5AH at 60 Hz
3 1 A1 ASSIGN 08H
3 2 A2 ASSIGN 09H
3 3 A3 ASSIGN 0AH
3 4 A4 ASSIGN 0BH
4 1 MODE 01H
Setup-Parameter for
Editing-Systems
BVE 9000
(Software Version 2)