SDS
Golden Power Corporation (HK) Ltd.
CR Battery
Ref.No.:GPSDS-CR-2020A
NA=Not Applicable
Page 2 / 6
CR1620
0.025
CR1632
0.04
Section 4 - First Aid Measures
None unless internal materials exposure. If contents are leaked out, observe following instructions.
Inhalation,
Fumes can cause respiratory irritation. Remove to fresh air and consult a physician.
Skin
Immediately flush skin with plenty of water. If itch or irritation by chemical burn
persists, consult a physician
Eyes
Immediately flush skin with plenty of water. If itch or irritation by chemical burn
persists, consult a physician
Immediately flush eye with plenty of water for at least 15 minutes. Consult a
physician immediately.
Ingestion
If swallowing a battery, consult a physician immediately.
If contents come into mouth, immediately rinse by plenty of water and consult a
physician.
Section 5 - Fire Fighting Measures
Extinguishing Media
Extinguisher of alkaline metal fire is effective.
Plenty of cold water is also effective to cool the surrounding area
and control the spread fire. But hydrogen gas may be evolved
by
the reaction of water and lithium and it can form an explosive
mixture. Therefore in the case that lots of lithium batteries are
burning in a confined space, use a smothering agent (e.g.
carbon dioxide or dry sand).
Fire fighting procedure
Use self-contained breathing apparatus and full protective
gear not to inhale harmful gas.
Section 6 - Accidental Release Measures
If the battery releases liquid, wipe it with a dry cloth.
Keep the battery away from fire or heat
Section 7 - Handling and Storage
1) Handling
● Never swallow.
●
If a battery is accidentally swallowed, see Section 4 - First Aid Measures