Instruction Manual
P/N: 4GL020-010
©2008 Vortech Engineering, LLC
All Rights Reserved, Intl. Copr. Secured
08OCT08 v5.0(99-07 GM Trk (4GLv5.0))
21
For internally lubricated V3 units only
This supercharger has been factory pre‑lled with spe-
cial Vortech synthetic lubricant. Oil does not need to be
added to a brand new unit; however a uid level check
should be performed.
Prior to operating the supercharger on the vehicle and
after installation onto the vehicle:
Remove the factory installed at‑head brass shipping
plug (not the dipstick) from the top of the supercharger
case. Replace the sealed shipping plug with the sup-
plied “vented” plug. Do not operate the supercharger
without it. Check the supercharger uid level.
Fluid level checking procedure:
1. Ensure that the .06” copper sealing washer is
located on the dipstick base.
2. Thread the clean dipstick into the supercharger
unit it seats.
3. Once the dipstick has seated, remove the dip-
stick from the unit. Fluid should register in the
crosshatched area on the dipstick.
4. DO NOT OVERFILL!!! Drain excess fluid the
unit if it is above the maximum level on the dip-
stick.
Check the uid level using the dipstick at least every
2,500 miles.
Initial supercharger uid change must be performed at
2,500 miles. The supercharger uid must be changed
at least every 7,500 miles.
Drain the uid, rell the unit with 4 oz. of Vortech V3
lubricating uid and then conrm proper oil level using
the dipstick. DO NOT OVERFILL!!!
WARNING: UseofanyotheruidotherthanthespecialVortech
lubricant will void the warranty and may cause compo-
nent failure.
16. FINAL ASSEMBLY AND CHECK, CONT'D