Fig 6U
Fig 6T
Fig 6V
T. Using a ½” ratchet or breaker bar, de-tension
the spring tensioner and install the supplied
10-rib belt as follows:
i. Around the 10-rib crank pulley.
ii. Under the spring tensioner.
iii. Around the supercharger pulley.
iv. On top side of the fixed idler.
See Fig 6T, 6U, 6V.
U. Oil Drain:
i. Self-Contained units only: Route the
end of the remote drain line from the
bottom of the supercharger to a location
where it can be conveniently be
accessed to perform oil changes. Use
zip ties to secure the line away from
moving parts, hot surfaces, and sharp
edges.
ii. Oil-Fed units only: Route the oil drain
hose down to the ½” fitting previously
installed into the oil pan. The hose must
be routed “downhill” free from kinks and
tight bends, and secured away from
moving parts, hot surfaces, and sharp
edges. Trim hose if necessary.