Specifications
GRDF / GRCF SERIES GAS FRYERS 
VULCAN-HART        F-31214 Rev. D (March 2008) 
-27- 
MAINTENANCE 
     Hot oil and hot parts can cause burns. Use care when operating, 
  cleaning, and servicing the fryer. 
     Spilling hot fryer compound can cause severe burns. Do not 
   move fryer without draining all frying compound from the tank. 
FLUE VENT INSPECTION 
When the fryer is cool, inspect annually. Check the flue and clear any obstructions. 
Service in the US and Canada 
Contact you local Vulcan-Hart Service office or address on the front of this manual. 
In Australia 
Contact Hobart Food Equipment PTY. LTD., 16 Hilly Street Morlake, N.S.W. 2137 Australia; 
P.O. Box 100, Concord N.S.W. 2137; Tel: (02) 9736 1200; Fax: (02) 9736 1555. 
www.hobartfood.com.au 
ALARMS AND ERROR MESSAGES 
PILOT OUT – If the pilot is out, the digital control displays the following message: 
        “D” Solid State – NO PLIOT 
        “C” Computer – PILOT OUT 
If no action is taken after 90 seconds, an alarm sounds continuously, the heat demand is 
disabled and any running cooking cycles are cancelled. The digital display the following 
message: 
        “D” Solid State – IGNITION LOCKOUT 
 “C” Computer – IGNITION   LOCKOUT 
The fryer must be turned off, then back on before the pilot can be re-initialized and normal 
functions resumed. 