Specifications
GRDF / GRCF SERIES GAS FRYERS 
VULCAN-HART        F-31214 Rev. D (March 2008) 
-6- 
Clearances 
  Minimum clearance from combustible construction: 
6” (15 cm) from the sides of the fryer 
6” (15 cm) from the back of the fryer 
The fryer may be installed on combustible floors 
  Minimum clearance from noncombustible construction: 
0” from the sides of the fryer 
0” from the back of the fryer 
  Between the fryer and any open-top flame units: 
16” (41 cm) 
  Allow space for servicing and operation. 
Location 
  Install fryer in an area with sufficient air supply for gas combustion at fryer 
 burners. 
  Do not obstruct the flow of combustion and ventilation air. 
  Provide adequate clearance for air openings into the combustion chamber. 
  Do not permit fans to blow directly onto fryer. 
  Avoid wall-type fans, which create cross-currents within a room. Avoid 
 open windows next to sides or back. 
CODES AND STANDARDS 
The fryer must be installed in accordance with: 
In the United States: 
  State and local codes, or in the absence of local codes, with: 
  National Fuel Gas Code, ANSI-Z223.1/NFPA #54 (latest edition). Copies may 
 be obtained from The American Gas Association Accredited Standards 
Committee Z223, @ 400 N. Capital St. NW, Washington, DC 20001 or the 
Secretary Standards Council, NFPA, 1 Batterymarch Park Quincy, MA 02169-
7471. 
  NFPA Standard #96 Vapor Removal from Cooking Equipment, latest edition, 
available from the National Fire Protection Association, Batterymarch Park, 
Quincy, MA. 02169-7471. 
  National Electrical Code, ANSI/NFPA-70 (latest edition). Copies may be obtained 
from The National Fire Protection Association, Batterymarch Park, Quincy, 
MA. 02169-7471. 