Hot Beverage Maker User Manual

— 8 —
DIRECT STEAM KETTLES
INSTALLATION PROCEDURE
Make sure the kettle is in its nal location before performing the installation procedure.
It may be necessary to increase the height of the kettle when leveling to clear the draw-off valve on
tilting kettles. Use the adjustable ange feet to increase the height of the kettle.
1. Place a spirit level on the rim of the kettle with the cover open. Adjust the feet to level the kettle
left-to-right and front-to-back.
2. Mark anchoring hole locations through the anged feet, then move the kettle out of the way.
3. With hole location marked, drill holes for expansion plugs for appropriate-sized lag bolts.
4. Reposition the kettle and verify that the kettle is level.
5. Bolt the kettle down and apply an NSF-approved silicone sealant around the bolt heads and
ange making contact with oor surface. Wipe off excess sealant immediately.
STEAM SUPPLY CONNECTION
The steam line plumbing diagram (Fig. 1) is a generic representation of the recommended steam
supply.
Fig. 1
If the incoming steam pressure is greater than kettle maximum operating pressure stamped on the
nameplate, install a pressure-reducing valve (not supplied) on the line before the steam inlet to the kettle.
Connect steam supply line (see chart) pipe size to the kettle inlet tting making sure there is a steam
control valve strainer. The steam supply line must be as large as the steam inlet tting.
The relief valve on the kettle must not be closed off as it is set to relieve excess pressure in the kettle.
If the steam is heavy with condensate, install a steam trap before the pressure regulator valve. To
ensure rapid heat-up of heavy loads, a ball oat type steam trap is recommended. Steam trap should
be sized for ow-rate and differential pressure. The steam supply line must be sized to maintain
pressure and ow (see chart).
A steam line pressure gauge (not supplied) is recommended to determine the actual steam pressure
being supplied to the kettle.
Install the steam shut-off valve at a convenient location near the kettle on the incoming steam line.
UNION
STRAINER
TO DRAIN
STEAM IN
STEAM IN
(TO KETTLE )
RELIEF VALVE
(50 PSI)
PRESSURE
GAUGE
PRESSURE
REDUCING
VALVE
SHUT-OFF
VALVE
STEAM TRAP
ON DRIP LEG