Fryer User Manual

GR SERIES GAS FRYERS - REMOVAL AND REPLACEMENT OF PARTS
F25125 (March 2003)
Page 5 of 24
SPECIFICATIONS
Electrical
120VAC supply for Filter-Ready fryers and
Kleenscreen filter models only. The filter pump
motor draws approximately 5 amps.
Gas Pressures
Manifold (per fryer section):
Natural - 4" W.C.
Propane - 10" W.C.
Building supply pressure (Min):
Natural - 5" W.C. (7" W.C. battery units)
Propane - 11" W.C. (12" W.C. battery units)
NOTE: Propane or Natural gases -14" W.C. (Max).
Input BTU Rating
GR SERIES
NO. OF
TUBES
BTU/HR/SECTION
GR25, GR25F 2 60,000
GR35, GR35F 3 90,000
GR45, GR45F 4 120,000
GR65, GR65F 5 150,000
GR85, GR85F 5 150,000
TOOLS
Standard
Standard set of hand tools.
VOM with AC current tester.
NOTE: Any quality VOM with a sensitivity of
20,000 ohms per volt can be used.
Temperature tester (thermocouple type).
U-Tube Manometer.
Pipe joint compound suitable for use with
propane gas.
REMOVAL AND REPLACEMENT OF PARTS
FRONT PANEL
WARNING: DISCONNECT THE
ELECTRICAL POWER TO THE
MACHINE AND FOLLOW LOCKOUT /
TAGOUT PROCEDURES.
1. Open fryer door and remove screws from front
panel.
2. Lift front panel from fryer.
3. Reverse procedure to install.
DOOR
1. Open the fryer door and remove screws
securing hinge & door assembly to fryer.