7. [ uuuu ] is displayed in the TIME display and the maximum steam
generator temperature setting is displayed in the TEMPERATURE
display. This value must be adjusted for the elevation (see Elevation
vs. Boiling Temperature Table, below). Rotate the adjustment knob
clockwise to increase or counterclockwise to decrease the numeric
value. Press
TIME to advance to the next step.
8. [ CCCC ] is displayed in the TIME display and the maximum convection
oven temperature setting is displayed in the TEMPERATURE display.
This value can be adjusted from 482°F to 518°F. It is recommended
the [ CCCC ] setting be 518°F. Rotate the adjustment knob
counterclockwise to decrease or clockwise to increase the numeric
value. Press
TIME to advance to the next step.
9. Set the Minimum and Maximum Values in steps 10 and 11 according
to the F
AN MOTOR COEFFICIENTS TABLE, below, the motor manufacturer's
label and the number of convection fan motors in the oven.
10. [ 1 - - ] is displayed in the TIME display and the Minimum Value is
displayed in the TEMPERATURE display. Rotate the adjustment knob
clockwise to increase or counterclockwise to decrease the Minimum
Value according to the table above. Press
TIME to advance to the
next step.
11. [ 2 - - ] is displayed in the TIME display and the Maximum Value is
displayed in the TEMPERATURE display. Rotate the adjustment knob
clockwise to increase or counterclockwise to decrease the Maximum
Value according to the table above. Press
TIME to advance to the
next step.
12. To repeat the Configuration Mode process from step 2, press
.
To exit Configuration Mode and save all settings, press the START
button.
NOITAVELE
leveLaeS
.tF005ot
ot005
.tF0001
ot0001
.tF0002
ot0002
.tF0003
ot0003
.tF0004
ot0004
.tF0005
ot0005
.tF0006
ot0006
.tF0007
ot0007
.tF0008
ot0008
.tF0009
ot0009
000,01
.tF
evobA
000,01
.tF
GNILIOB
ERUTAREPMETERUTAREPMET
ERUTAREPMET
ERUTAREPMETERUTAREPMET
)RETAW()RETAW(
)RETAW(
)RETAW()RETAW(
O
F
212
O
F112
O
F902
O
F702
O
F502
O
F402
O
F202
O
F002
O
F891
O
F691
O
F591
O
F491
O
F
FAN MOTOR COEFFICIENTS TABLE
Number of Minimum Value Maximum Value
Motor Manufacturer(s) Convection Fan 1 - - 2 - -
Motors See step 10. See step 11.
Leroy-Somer (Hanning) 1 08 60
Brook-Crompton 1 08 60
Both motors by Leroy-Somer (Hanning) 2 26 130
Both motors by Brook-Crompton 2 26 130
1 motor by Leroy-Somer (Hanning) and
2 26 130
1 motor by Brook Crompton