User manual

– 4 –
Installation, Operation, and Care of
GCO2D & GCO2C
GAS CONVECTION OVENS
KEEP THIS MANUAL FOR FUTURE USE
GENERAL
The GCO2D Gas Convection Oven is a single cavity oven and features a solid state thermostat, 1-hour
dial timer, and five racks as standard equipment. Additional oven racks are optional. Each oven is
equipped with a 25,000 Btu/hr burner and a
1
2 HP (0.37 kw) electric motor. The oven comes standard
with painted grey exterior and porcelain interior; stainless steel interior and exterior are optional.
Stainless steel door with window (door hinging is field reversible) and stainless steel front are standard.
Model GCO2C has different controls than the GCO2D.
Two single ovens can be ordered with a stacking kit for mounting one oven on top of the other.
A single oven may be installed on an open stand with lower storage rack (optional).
Your Vulcan Gas Convection Oven is produced with quality workmanship and material. Proper
installation, usage and maintenance of your oven will result in many years of satisfactory performance.
Vulcan-Hart Company suggests that you thoroughly read this entire manual and carefully follow all of
the instructions provided.
LEDOMLEDOM
LEDOM
LEDOMLEDOMTATSOMREHTTATSOMREHT
TATSOMREHT
TATSOMREHTTATSOMREHTREMITREMIT
REMIT
REMITREMIT
&TSAOR&TSAOR
&TSAOR
&TSAOR&TSAOR
DLOHDLOH
DLOH
DLOHDLOH
ELTNEGELTNEG
ELTNEG
ELTNEGELTNEG
EKABEKAB
EKAB
EKABEKAB
KOOC#KCARKOOC#KCAR
KOOC#KCAR
KOOC#KCARKOOC#KCAR
SEMITSEMIT
SEMIT
SEMITSEMIT
D2OCGetatSdiloSlaiDruoH-1
9991rebotcOerofebC2OCGcinortcelEcinortcelEXX
9991rebotcOretfaC2OCGelbammargorPelbammargorPX X
INSTALLATION
UNPACKING
Immediately after unpacking the oven, check for possible shipping damage. If this oven is found to be
damaged, save the packaging material and contact the carrier within 15 days of delivery.
Prior to installation, verify that the electrical supply and type of gas (natural or propane) agree with the
specifications on the oven data plate, located on the inside of the top front cover.
Do not use the door or its handle to lift the oven.
LOCATION
The equipment area must be kept free and clear of combustibles. Clearance from combustible or non-
combustible construction of at least 3"
(7.6 cm) on the sides and 3" (7.6 cm) at the back are required. The
installation location must allow adequate clearance for servicing and proper operation.
The oven must be installed so that the flow of combustion and ventilation air will not be obstructed.
Adequate clearance for air openings into the combustion chamber must be provided. Make sure there
is an adequate supply of air in the room to allow for combustion of gas at the oven burners.