Service manual

VSX SERIES STEAMER - REMOVAL AND REPLACEMENT OF PARTS
Page 13 of 40
(
Electric Model Shown)
GAS IGNITION MODULE
WARNING:
DISCONNECT THE ELECTRICAL
POWER TO THE MACHINE AT THE MAIN
CIRCUIT BOX. PLACE A TAG ON THE CIRCUIT
BOX INDICATING THE CIRCUIT IS BEING
SERVICED.
1. Remove the right side panel as outlined under
"COVERS AND PANELS".
2. Disconnect the control wires by pulling off wire
harness connector located on the right side of
module.
3. Remove screws that secure the module to the
control board and lift off.
4. Reverse the procedure to install the new gas
ignition module then check for proper operation.
STEAM GENERATOR TANK
WARNING:
DISCONNECT THE ELECTRICAL
POWER TO THE MACHINE AT THE MAIN
CIRCUIT BOX. PLACE A TAG ON THE CIRCUIT
BOX INDICATING THE CIRCUIT IS BEING
SERVICED.
1. Turn off the water supply and allow hot parts to
cool down if necessary. On gas models, shut the
gas supply off to the unit.
2. Remove the right side panel and top cover as
outlined under "COVERS AND PANELS".
3. Manually drain steam generator tank if
necessary, as outlined under "DRAIN TANK
MANUALLY".
4. Disconnect the lead wire from each water level
probe and then remove probes from tank. Mark
probes accordingly for replacement.