Service manual

VSX SERIES STEAMER - REMOVAL AND REPLACEMENT OF PARTS
Page 16 of 40
5. Use a hammer and punch to turn the stem
counterclockwise to remove the stem from the
body.
6. All parts are now accessible for inspection and
cleaning.
A. Check rubber seal on bottom of plunger.
B. Check plunger spring.
C. Check "O"ring in valve body.
D. Check ports in valve body.
7. Reverse procedure to install.
DRAIN VALVE
WARNING:
DISCONNECT THE ELECTRICAL
POWER TO THE MACHINE AT THE MAIN
CIRCUIT BOX. PLACE A TAG ON THE CIRCUIT
BOX INDICATING THE CIRCUIT IS BEING
SERVICED.
Removal
1. Turn off the water supply to the steamer.
2. Remove the right side panel and top cover as
outlined under "COVERS AND PANELS".
3. Manually drain the steam generator tank if
necessary, as outlined under "DRAIN TANK
MANUALLY".
4. Disconnect the lead wires from the water level
control and the ground wire from the control
panel if necessary, to access the drain valve
connections.
5. Disconnect the fittings on each side of the valve
and remove the valve from the unit.
6. Reverse procedure to install.
Disassembly
1. Turn off the water supply to the steamer.
2. Remove the right side panel as outlined under
"COVERS AND PANELS".
3. Manually drain the steam generator tank if
necessary, as outlined under "DRAIN TANK
MANUALLY".
4. Remove the cover from the drain valve motor.