Service manual

VSX SERIES STEAMER - TROUBLESHOOTING
SYMPTOM POSSIBLE CAUSES
Page 39 of 40
Tank does not fill. 1. Water supply not on.
2. Fill solenoid 1SOL not opening or plugged.
3. Water level control malfunction (WLC).
4. Water level probes shorted to ground.
Timer motor does not run. 1. Door open or door switch 2S inoperative.
2. 2K-1 NC/C contacts not closing.
3. Timer inoperative.
Water running out of drain during fill or
when the power switch 1S is off.
1. 1SOL stuck open.
2. 2SOL stuck open.
Delime light does not reset after power
switch has been moved to de-lime
position.
1. Relay 3K-2 open.
2. Delime timer board malfunction.
Delime timer board LED is not lit when
time is dialed into cook timer.
1. NC contacts of 3K-1 open.
2. Transformer inoperative.
3. Current sensor malfunction.
4. Delime timer board malfunction.
Delime light does not light after pre-set
time. (Delime timer board LED lights.)
1. Delime light open.
2. Delime timer board malfunction.
Door not closing properly. 1. Door latch assembly.
2. Striker adjustment.
Door wont open. 1. Latch wont release see DOOR LATCH ADJUSTMENT in
SERVICE PROCEDURES AND ADJUSTMENTS.
Buzzer not operating. 1. Timer malfunction.
2. Buzzer malfunction.